PubMed Health⌕ Search

PubMed · 16585624

Measuring runoff-suspended solids using an improved turbidometer method.

Abstract

Differences in particle size distribution between runoff standards and unknown samples affect the accuracy of estimation of total suspended solids (TSS) concentration using the nephelometric turbidity (NTU) method. The objective was to quantify the effects of a sucrose solution as suspending medium and contrasting particle size distribution on nephelometric turbidity and accuracy of TSS estimation. Nineteen benchmark soils varying in texture and color were divided into particle size distribution of <250 and <2000 microm. Soils from these two aggregate classes were then made into suspension ranging from 0.2 to 15 g L-1 using distilled deionized water. Runoff suspensions ranging from 0.2 to 21 g L-1 were also collected from different watersheds. Turbidity of soil and runoff suspensions was measured in sucrose solution and in distilled deionized water. The sucrose solution density ranged from 1.10 to 1.30 kg L-1. Increasing sucrose solution density decreased turbidity. The TSS concentration was most sensitive to changes in turbidity with the 1.30 kg L-1 sucrose solution. Using the 1.30 kg L-1 sucrose solution, particle size bias and error of TSS estimates were decreased by at least 20% compared to distilled deionized water. Reduction in refraction index differences between the suspended particles and sucrose solution combined with reduced particle settling and reduced Brownian motion resulted in dampening the effects of particle size distribution. We propose a sucrose solution of 1.30 kg L-1 as a better suspending medium to dampen the effect of particle size distribution and thus improve suspension TSS concentration estimation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel Ginting, Martha Mamo. 2006-04-03. Measuring runoff-suspended solids using an improved turbidometer method.. https://doi.org/10.2134/jeq2005.0219

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Application of highly accurate nephelometric titration in the assaying of phenytoin sodium.

AIM: To determine phenytoin sodium by a highly accurate nephelometric titration. METHODS: The titration operating conditions were optimized and the solubility product constant of phenytoin silver precipitation was determined. RESULTS: The result of the titration is comparable to those of control experiments. CONCLUSION: The proposed method has been found to be accurate, precise, specific, reproducible, and linear.

Nephelometry and Turbidimetry↗

Determination of promethazine hydrochloride and its preparations by highly accurate nephelometric titration.

A highly accurate nephelometric titration for the determination of promethazine hydrochloride and its preparations was presented. The titration operating conditions were studied and the solubility product constant of promethazine tetraphenylboron precipitation was determined. The result of the titration is comparable to those of control experiments. The proposed method has been found to be accurate, precise, specific and linear.

Nephelometry and Turbidimetry↗

Determination of norfloxacin by highly accurate nephelometric titration.

A highly accurate nephelometric titration for the determination of norfloxacin is presented. The titration operating conditions were studied and the solubility product constant of norfloxacin-tetraphenylboron precipitation was determined. The result of the titration is comparable to those of control experiments. The proposed method has been found to be accurate, precise, specific, and linear.

Nephelometry and Turbidimetry↗