PubMed Health⌕ Search

PubMed · 16604940

Predictable root recession coverage.

Abstract

Gingival recession, exposure of the tooth's root, is undesirable and, in many situations, contrary to normal physiology. Today's root coverage is predictable. With the use of an acellular dermal matrix membrane (Fasciablast), we can achieve a new blood supply and predictable coverage, with no second surgical procedure. Youth, esthetics and physiology are restored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David L Hoexter. 2006. Predictable root recession coverage.. https://pubmed.ncbi.nlm.nih.gov/16604940/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Colloidal lithography and current fabrication techniques producing in-plane nanotopography for biological applications.

Substrate topography plays a vital role in cell and tissue structure and function in situ, where nanometric features, for example, the detail on single collagen fibrils, influence cell behaviour and resultant tissue formation. In vitro investigations demonstrate that nanotopography can be used to control cell reactions to a material surface, indicating its potential application in tissue engineering and implant fabrication. Developments in the catalyst, optical, medical and electronics industries have resulted in the production of nanopatterned surfaces using a variety of methods. The general protocols for nanomanufacturing require high resolution and low cost for fabricating devices. With respect to biological investigations, nanotopographies should occur across a large surface area (ensuring repeatability of experiments and patterning of implant surfaces), be reproducible (allowing for consistency in experiments), and preferably, accessible (limiting the requirement for specialist equipment). Colloidal lithography techniques fit these criteria, where nanoparticles can be utilized in combination with a functionalized substrate to produce in-plane nanotopographies. Subsequent lithographic processing of colloidal substrates utilizing, for example, reactive ion etching allows the production of modified colloidal-derived nanotopographies. In addition to two-dimensional in-plane nanofabrication, functionalized structures can be dip coated in colloidal sols, imparting nanotopographical cues to cells within a three-dimensional environment.

Biocompatible Materials↗

Nonlinear mechanics of soft fibrous networks.

Mechanical networks of fibres arise on a range of scales in nature and technology, from the cytoskeleton of a cell to blood clots, from textiles and felts to skin and collageneous tissues. Their collective response is dependent on the individual response of the constituent filaments as well as density, topology and order in the network. Here, we use the example of a low-density synthetic felt of athermal filaments to study the generic features of the mechanical response of such networks including strain stiffening and large effective Poisson ratios. A simple microscopic model allows us to explain these features of our observations, and provides us with a baseline framework to understand active biomechanical networks.

Biocompatible Materials↗

Poly(lactic-co-glycolic acid) hollow fibre membranes for use as a tissue engineering scaffold.

Mass transfer limitations of scaffolds are currently hindering the development of 3-dimensional, clinically viable, tissue engineered constructs. We have developed a poly(lactide-co-glycolide) (PLGA) hollow fibre membrane scaffold that will provide support for cell culture, allow psuedovascularisation in vitro and provide channels for angiogenesis in vivo. We produced P(DL)LGA flat sheet membranes using 1, 4-dioxane and 1-methyl-2-pyrrolidinone (NMP) as solvents and water as the nonsolvent, and hollow fibre membranes, using NMP and water, by dry/wet- and wet-spinning. The resulting fibres had an outer diameter of 700 micro m and an inner diameter of 250 micro m with 0.2-1.0 micro m pores on the culture surface. It was shown that varying the air gap and temperature when spinning changed the morphology of the fibres. The introduction of a 50 mm air gap caused a dense skin of 5 micro m thick to form, compared to a skin of 0.5 micro m thick without an air gap. Spinning at 40 degrees C produced fibres with a more open central section in the wall that contained more, larger macrovoids compared to fibres spun at 20 degrees C. Culture of the immortalised osteogenic cell line 560pZIPv.neo (pZIP) was carried out on the P(DL)LGA flat sheets in static culture and in a P(DL)LGA hollow fibre bioreactor under counter-current flow conditions. Attachment and proliferation was statistically similar to tissue culture polystyrene on the flat sheets and was also successful in the hollow fibre bioreactor. The P(DL)LGA hollow fibres are a promising scaffold to address the size limitations currently seen in tissue engineered constructs.

Biocompatible Materials↗