Kidney function estimating equations: where do we stand?

Abstract

PURPOSE OF REVIEW: Estimation of the glomerular filtration rate (GFR) is central to the diagnosis, evaluation and management of chronic kidney disease. This review summarizes recent data on the performance of equations using serum creatinine to estimate the GFR, particularly the Modification of Diet in Renal Disease (MDRD) Study equation. RECENT FINDINGS: During 2005 GFR estimation has received substantial attention with a focus on comparing the MDRD Study equation with the Cockcroft-Gault equation. Several large studies (n>500) have appeared. Most studies discuss creatinine calibration but few were able to standardize measurements. Studies that did calibrate the creatinine had improved performance. Overall, the MDRD Study equation performed well in populations with a low range of GFR and often outperformed the Cockcroft-Gault equation. Both equations have lower precision in high GFR populations, and the MDRD equation under-estimated the GFR in a number of studies. Efforts are underway to develop improved prediction equations by pooling data across many study populations. SUMMARY: Equations for estimating the GFR from serum creatinine are useful for systematic staging of chronic kidney disease. The MDRD Study equation and systematic creatinine assay calibration improve the level of precision and accuracy in many settings. GFR estimates are less useful in the normal range of GFR, however, and are sensitive to the population under study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Josef Coresh, L A Stevens. 2006. Kidney function estimating equations: where do we stand?. https://doi.org/10.1097/01.mnh.0000222695.84464.61

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chemical images: technical approaches and issues.

Chemical mapping techniques using Raman microscopy are introduced, and using an example of a pharmaceutical tablet, the practical aspects of data collection and processing to produce a chemical image of the sample are detailed. Issues related to data processing, instrument standards, chemical image reportable errors, and the interpretation of chemical images are presented to encourage debate, develop solutions, and promote use in other challenging scientific applications. applications.

Calibration↗

Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system.

PURPOSE: Dynamically compensating for target motion during radiotherapy will increase treatment accuracy. A laboratory system for real-time target tracking with a dynamic MLC has been developed. In this study, the geometric accuracy limits of this DMLC target tracking system were evaluated. METHODS AND MATERIALS: A motion simulator was programmed to follow patient-derived tumor motion paths, parallel to the leaf motion direction. A target attached to the simulator was optically tracked, and the leaf positions adjusted to continually align the DMLC beam aperture to the target. Analysis of the tracking accuracy was based on video images of the target and beam alignment. The system response time was determined and the tracking error measured. Response time-corrected tracking accuracy was also calculated to investigate the accuracy limits of an improved system. RESULTS: The response time of the system is 160 +/- 2 ms. The geometric precision for tracking patient motion is 0.6 to 1.1 mm (1 sigma) for the 3 patient datasets tested, with tracking errors relative to the original patient motion of 35, 40, and 100%. CONCLUSIONS: A DMLC target tracking system has been developed that can account for detected motion parallel to the leaf motion direction. The tracking error has a negligible systematic component. Reducing the response time will further increase the overall system accuracy.

Calibration↗

Mass discrimination during MC-ICPMS isotopic ratio measurements: investigation by means of synthetic isotopic mixtures (IRMM-007 series) and application to the calibration of natural-like zinc materials (including IRMM-3702 and IRMM-651).

A long known way of anchoring isotope ratio values to the SI system is by means of gravimetrically prepared isotopic mixtures. Thermal ionization mass spectrometry (TIMS) is the traditionally associated measurement technique, but multi-collector double focusing inductively coupled plasma (MC-ICP)-MS now appears to be an attractive alternative. This absolute calibration strategy necessitates that mass discrimination effects remain invariant in time and across the range of isotope ratios measured. It is not the case with MC-ICPMS and the present work illustrates, in the case of Zn isotopic measurements carried out using locally produced synthetic Zn isotope mixtures (IRMM-007 series), how this calibration strategy must be adjusted. First, variation in mass discrimination effects across the measurement sequence is propagated as an uncertainty component. Second, linear proportionality during each individual measurement between normalized mass discrimination and the average mass of the isotope ratios is used to evaluate mass discrimination for the ratios involving low abundance isotopes. Third, linear proportionality between mass discrimination and the logarithm of the isotope ratio values for n(67Zn)/n(64Zn) and n(68Zn)/n(64Zn) in the mixtures is used iteratively to evaluate mass discrimination for the same ratios in the isotopically enriched materials. Fourth, ratios in natural-like materials (including IRMM-3702 and IRMM-651) are calibrated by external bracketing using the isotopic mixtures. The relative expanded uncertainty (k = 2) estimated for n(68Zn)/n(64Zn) and n(67Zn)/n(64Zn) ratio values in the synthetic isotopic mixtures and the natural-like zinc samples was in the range of 0.034 to 0.048%. The uncertainty on the weighing (0.01%, k = 1) was the largest contributor to these budgets. The agreement between these results and those obtained with a single detector TIMS and with another MC-ICPMS further validated this work. The absolute isotope ratio values found for IRMM-3702-material also proposed as "delta 0" for delta-scale isotopic measurements-are n(66Zn)/n(64Zn) = 0.56397 (30), n(67Zn)/n(64Zn) = 0.082166 (35), n(68Zn)/n(64Zn) = 0.37519 (16), and n(70Zn)/n(64Zn) = 0.012418 (23). The derived Zn atomic weight value Ar(Zn) = 65.37777 (22) differs significantly from the current IUPAC value by Chang et al. [1]. Remeasurement, with isotopic mixtures from the IRMM-007 series, of the Zn isotope ratios in the same Chang et al. [1] material have revealed large systematic differences (1.35 (27)% per atomic mass unit) that suggest unrecognized measurement biases in their results.

Calibration↗