PubMed Health⌕ Search

PubMed · 16623035

The difference among stress and rest normal reference databases using non-corrected, scatter corrected, and scatter with attenuation corrected Bull's eye myocardial perfusion scintigraphy in both genders.

Abstract

OBJECTIVES: To compare 3 types of Bull's eye normal reference maps; non-corrected, scatter corrected, and scatter with attenuation corrected Bull's eye in both genders. MATERIAL AND METHOD: Sixty-seven normal healthy males and females volunteered for the present study. After screening tests to identify low post-test (exercise EKG) likelihood of coronary artery disease, 41 subjects (20 males and 21 females) had stress and rest myocardial perfusion scintigraphy (99mTc-sestamibi). The data were reconstructed by filtered back projection reconstruction in three ways as follows; (1) non-correction (NoC), (2) scatter elimination only (SC), (3) scatter elimination and attenuation correction (SC+AC). Three sets of reconstructed data of both stress and resting studies were added into 6 sets of Bull's eye. The data of each Bull's eve were normalized to 100% of the maximum count. Percentage of uptake in each area was compared by t-test statistics. RESULTS: Stress and rest count distribution of NoC and SC sets were lowest at the inferior wall, followed by the septal wall, anterior wall, and lateral wall in both genders. In the SC+AC sets; septum and lateral walls showed more uptake than anterior and inferior walls. A significant difference of percentage uptake between stress and rest images at septum in NoC and SC images in male and in SC image in female was observed. No difference was seen in the SC+AC groups. CONCLUSION: There was similarity of count distribution between NoC and SC images. SC+AC caused more uniform image. However; some non-uniformity was observed. The use of sex-independent SC+AC bull's eye is possible. Stress study can be omitted for bull's eye collection of normal files.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Supatporn Tepmongkol, Panya Pasawang, Anchali Krisanachinda, Suphot Srimahachota. 2005. The difference among stress and rest normal reference databases using non-corrected, scatter corrected, and scatter with attenuation corrected Bull's eye myocardial perfusion scintigraphy in both genders.. https://pubmed.ncbi.nlm.nih.gov/16623035/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗