PubMed · 16632719

Computer-aided detection in screening CT for pulmonary nodules.

Abstract

OBJECTIVE: Our objective was to evaluate the performance of a computer-aided detection (CAD) system for pulmonary nodule detection using low-dose screening CT images. MATERIALS AND METHODS: One hundred fifty consecutive low-dose screening CT examinations were independently evaluated by a radiologist and a CAD pulmonary nodule detection system (R2 Technology) designed to identify nodules larger than 4 mm in maximum long-axis diameter. All discrepancies between the two techniques were reviewed by one of another two radiologists working in consensus with the initial interpreting radiologist, and a "true" nodule count was determined. Detected nodules were classified by size, density, and location. The performance of the initial radiologist and the CAD system were compared. RESULTS: The radiologist detected 518 nodules and the CAD system, 934 nodules. Of the 1,106 separate nodules detected using the two techniques, 628 were classified as true nodules on consensus review. Of the true nodules present, the radiologist detected 518 (82%) of 628 nodules and the CAD, 456 (73%) of 628 nodules. All 518 radiologist-detected nodules were true nodules, and 456 (49%) of 934 of CAD-detected nodules were true nodules. The radiologist missed 110 true nodules that were only detected by CAD. In six patients, these were the only nodules detected in the examination, changing the imaging follow-up protocol. CAD identified 478 lesions that on consensus review were false-positive nodules, a rate of 3.19 (478/150) per patient. CONCLUSION: CAD detected 72.6% of true nodules and detected nodules in six (4%) patients not identified by radiologists, changing the imaging follow-up protocol of these subjects. In this study, the combined review of low-dose CT scans by both the radiologist and CAD was necessary to identify all nodules.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ren Yuan, Patrick M Vos, Peter L Cooperberg. 2006. Computer-aided detection in screening CT for pulmonary nodules.. https://doi.org/10.2214/ajr.04.1969

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Use of a screening device for sleep apnea in clinical practice].

About 2-4% of adults suffer from obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder (SRBD). Repetitive obstructions of the upper airway mean that it is associated with hypertension and an elevated cardio- and cerebrovascular morbidity, which can be lowered by means of effective therapy. These patients cannot be treated correctly unless they are identified early in the course of the condition. Therefore, this study evaluated the use of the microMESAM screening device (known up to December 2005 as the "ApneaLink") in 61 patients in whom SRBD was suspected. The device proved reliable and practical in application.

Diagnosis, Computer-Assisted↗

Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

RATIONALE AND OBJECTIVES: We developed a computerized scheme for detection of lung nodules in the lateral views of chest radiographs, in order to improve the overall performance in combination with the computer-aided diagnostic (CAD) scheme for posterior-anterior (PA) views. MATERIALS AND METHODS: We used 106 pairs of PA and lateral views of chest radiographs (122 lung nodules) for development of the CAD scheme. In the CAD scheme for lateral views, initial candidates of lung nodules were identified by use of a nodule enhancement filter based on the edge gradients. Thirty-four image features extracted from the original and the nodule-enhanced images were used for the rule-based scheme and for artificial neural networks (ANNs) for removal of some false-positive candidates. The computer performance was evaluated with a leave-one-case-out test method for ANNs. For PA views, we used the existing CAD scheme, which was trained with one-half of 924 chest images and then tested with the remaining images. RESULTS: When the CAD scheme was applied only to PA views, the sensitivity in the detection of lung nodules was 70.5%, with 4.9 false positives per image. Although the performance of the computerized scheme for lateral views was relatively low (60.7% sensitivity with 1.7 false positives per image), the overall sensitivity (86.9%) was improved (6.6 false positives per two views), because 20 (16.4%) of the 122 nodules were detected only on lateral views. CONCLUSIONS: The CAD scheme by use of lateral-view images has the potential to improve the overall performance for detection of lung nodules on chest radiographs when combined with a conventional CAD scheme for standard PA views.

Diagnosis, Computer-Assisted↗

Improvement of the detection of myocardial ischemia thanks to information technologies.

BACKGROUND: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. METHODS: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. RESULTS: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. CONCLUSIONS: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia.

Diagnosis, Computer-Assisted↗