PubMed Health⌕ Search

PubMed · 16643093

Higher level chromatic mechanisms for image segmentation.

Abstract

We used a noise-masking paradigm to investigate the number and properties of chromatic mechanisms involved in image segmentation. Observers were presented with a pattern of dynamic random squares, each independently modulated along a certain direction in DKL color space, either in the isoluminant plane or in the L - M luminance plane. A signal consisting of a rectangular region of squares, oriented horizontally or vertically, was added to the noise. The signal squares were spatially and temporally aligned to the noise squares, excluding the possibility of phase offsets to mediate segmentation performance. Noise and signal color directions were independently varied, and the signal contrast was measured at which an observer could reliably indicate the orientation of the signal. In a second set of experiments, the noise was simultaneously varying in two directions, symmetrically arranged around the signal direction. Masking was generally highest when signal and noise were modulated along the same direction and minimal for orthogonal noise. No difference was found between signals modulated along cardinal directions or intermediate directions. However, measured tuning widths critically depended on the type of noise: Noise modulated along one direction results in narrow tuning, whereas two-sided noise results in broad tuning. A chromatic detection model with multiple broadly tuned mechanisms successfully accounts for the experimental findings, both for narrow and broad tuning curves. Models with four broadly tuned cardinal mechanisms or multiple narrowly tuned mechanisms failed to reproduce the data. Our results suggest an important role for multiple, broadly tuned mechanisms in image segmentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thorsten Hansen, Karl R Gegenfurtner. 2006-03-13. Higher level chromatic mechanisms for image segmentation.. https://doi.org/10.1167/6.3.5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗