PubMed Health⌕ Search

PubMed · 16644941

Development of a high range TLD dosemeter.

Abstract

Global Dosimetry Solutions Inc. has developed a high range TLD dosemeter capable of measuring high-energy photon doses to 1 KGy. Additional correction factors have been established for as many as 10 various X ray and beta sources, allowing for high range monitoring of other sources and energies from 500 to 1000 Gy. The product utilizes TLD-100 and TLD-700 chips, available in three different configurations of very small size, and is offered at an economical price. Data analysis is quick, providing results within 24 h in most cases. This report describes the testing completed to support this product, primarily the determination of the supralinearity corrections necessary for doses up to 1 KGy. The test results are considered preliminary due to minimal data points between 0.5 and 1.0 KGy. Additional irradiations are being conducted to establish a more accurate statistical curve at this high dose level. Due to the high dose residual these dosimeters are considered for single use only.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sander Perle. 2006-04-27. Development of a high range TLD dosemeter.. https://doi.org/10.1093/rpd%2Fnci679

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗