In this work a three-dimensional ferrous-ferric ion exchange dosemeter is proposed and the dose response measured. The dosemeter consists of strong acid cation exchange resin beads in the H form in water. Amberlyst 15 Wet beads with a harmonic mean diameter of 0.600-0.850 mm were prepared by soaking them in an aqueous solution of ferrous ammonium sulphate to exchange ferrous ions for H(+) ions. The beads were rinsed with distilled water and packed in glass vials. Sets of samples with ferrous ion concentrations of 0.5 and 1.0 mM were dosed with 6 MV X rays from a Varian 2100C linac. The spin-lattice relaxation time constants (T1) for the samples were measured using an Apollo spectrometer (Tecmag, Houston, TX) interfaced to a 1.5 T magnet (Magnex, Abingdon, UK). Each sample had two T1 values; a long T1 at 1200 ms that did not significantly change with dose and a short T1 that ranged from 56 ms at 0 Gy to 36 ms at 100 Gy. The R1 vs. dose responses were linear with slopes of 0.066 and 0.079 s(-1) Gy(-1).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John A Bauhs, Bruce E Hammer. 2006-04-27. Ferrous-Ferric Ion exchange dosemeter.. https://doi.org/10.1093/rpd%2Fnci594

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗