PubMed Health⌕ Search

PubMed · 16651175

New hamstring fixation technique for medial collateral ligament or posterolateral corner reconstruction using the mosaicplasty system.

Abstract

In this study, we describe a new hamstring fixation technique with a bone graft using the Mosaicplasty system for the reconstruction of the medial collateral ligament (MCL) or posterolateral corner (PLC) of the knee. In this technique, a cylindrical bone plug (6.5 mm in diameter, 15 mm in length) is harvested from the anatomical femoral attachment of the MCL or popliteal tendon using the Mosaicplasty system. After placing the autologous semitendinosus or gracilis tendon as a graft in the created bone socket, the bone plug is replaced over the graft. The graft is secured with a spike staple after appropriate tension is applied to the graft. This fixation technique can provide rigid and less invasive fixation, because the distance between the fixation sites can be shorter than that in the Endobutton technique. Compared to fixation with only a staple with no bone graft, the bone graft may enhance tendon to bone healing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nobuo Adachi, Mitsuo Ochi, Masataka Deie, Yasunori Izuta, Hiromi Kazusa. 2006. New hamstring fixation technique for medial collateral ligament or posterolateral corner reconstruction using the mosaicplasty system.. https://doi.org/10.1016/j.arthro.2006.01.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dry reagent dipstick test combined with 23S rRNA PCR for molecular diagnosis of bacterial infection in arthroplasty.

Periprosthetic joint infections present a challenging problem in orthopaedics. Conventional methods for detection of arthroplasty infections rely on bacterial culture of synovial fluid aspirates. During recent years, however, molecular tests that are based on DNA amplification by the polymerase chain reaction (PCR), followed by electrophoretic analysis of the products, have been introduced. We report a simple and inexpensive assay that allows visual detection and confirmation of the PCR-amplified sequences by hybridization within minutes. The assay is performed in a dry reagent dipstick format (strip) and does not require special instrumentation. Universal primers are used for PCR of the 23S ribosomal RNA (rRNA) gene. The biotinylated amplification product is hybridized with dA-tailed probes that are specific for six pathogens commonly involved in periprosthetic joint infections. The mixture is applied to the strip, which is then immersed in the appropriate buffer. The buffer migrates along the strip by capillary action and rehydrates gold nanoparticles with oligo(dT) strands attached to their surface. The nanoparticles bind to the target DNA through hybridization, and the hybrids are captured by immobilized streptavidin at the test zone of the strip, producing a characteristic red line. Unbound nanoparticles are captured by immobilized oligo(dT) strands at the control zone of the strip, generating a second line. The dipstick test was applied to the detection of Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Enterococcus faesium, and Haemophilus influenza. Twelve samples of synovial fluids from patients were analyzed for the detection and identification of the infection caused by the six pathogens. The results were compared with bacterial cultures.

Arthroplasty↗