PubMed Health⌕ Search

PubMed · 16677381

A universal reference sample derived from clone vector for improved detection of differential gene expression.

Abstract

BACKGROUND: Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs. RESULTS: We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. CONCLUSION: Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in combination with reference designs enable systems biology microarray experiments of small physiologically relevant changes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rishi L Khan, Gregory E Gonye, Guang Gao, James S Schwaber. 2006-05-05. A universal reference sample derived from clone vector for improved detection of differential gene expression.. https://doi.org/10.1186/1471-2164-7-109

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Consideration on calibration and correction factors of an Hp10 chamber for different radiation qualities and angles of incidence.

This paper presents the characterisation performed at IRSN (France) of an H(p)(10) chamber in terms of calibration coefficient and correction factors for the radiation qualities of ISO narrow spectrum series. The chamber response, expressed in H(p)(10) using conversion coefficients h(p)(K)(10; N, alpha) listed in ISO 4037-3 in the energy range from 30 to 1250 keV and for angles of incidence between 0 and 70 degrees, was found to be within approximately 10%. However, for photon energies <30 keV, an overresponse of the chamber that could reach 100% was observed. Nevertheless, this overresponse was reduced to 25% using the conversion coefficients estimated at Physikalisch-Technische Bundesanstalt (PTB). This implies that the X-ray spectra produced by the IRSN X-ray units are very similar to those produced by PTB, both containing a little bit more high-energy photons than the spectra used in ISO 4037-3. The dose rate dependence of the chamber tested by gamma radiation from (60)Co sources was found to be within 2% in the range of 0.3 mSv h(-1) to 1 Sv h(-1). The H(p)(10) chamber can measure directly the conventional true value of H(p)(10) after calibration by a reference laboratory, and can be used for transferring H(p)(10) reference quantities from a reference laboratory.

Calibration↗

Grayscale calibration and quality assurance of diagnostic monitors in a PACS system.

PURPOSE: The aim of this study was to calibrate monitors used in soft-copy review of diagnostic images in a pictures archiving and communication system (PACS) and to assess critical quality assurance (QA) parameters through appropriate checks. MATERIALS AND METHODS: Barco [cathode ray tube (CRT) and liquid crystal display (LCD)] and EIZO (LCD) monitors were evaluated. Calibration and QA controls were carried out during acceptance tests on the systems and every 6 months according to the Task Group 18 (TG18) report by the American Association of Physicists in Medicine (AAPM). The parameters in question include: maximum luminance, contrast ratio, luminance response, spatial resolution and angular response. A subjective evaluation of image quality was also conducted by a number of radiologists. RESULTS: Barco medical monitors' results were well within tolerances, with significant parameters persisting over time. EIZO nonmedical monitors showed rapid performance deterioration below the minimum requirements. Calibration had to be repeated only in a few cases. Radiologists' evaluations showed that monitor quality is equal to or even better than that of conventional films. CONCLUSIONS: Medical monitors turned out to be fully adequate to the task. Periodic QA tests are, however, absolutely necessary to ensure constant quality levels.

Calibration↗

Calibration of a 220Rn flow-through source.

Two reference methods have been established to calibrate the yield of a self-made 220Rn flow-through source. These reference methods include (a) a small scintillation cell flow-through method and (b) a gamma spectrometry method that takes advantage of an activated charcoal. The methods were validated theoretically and experimentally including intercomparison measurements. It is shown that the source is stable with a relative deviation less than 2.5% over 5 years, when the relative humidity ranged from 50 to 90%, and the temperature from 5 to 38 degrees C. The 220Rn monitor used in these reference methods is calibrated without a 220Rn gas source with determinate yield. On the basis of the calibration of the 220Rn source by the methods mentioned above, the accurate calibration of any 220Rn monitor by the self-made 220Rn source with stable yield is feasible.

Calibration↗