PubMed Health⌕ Search

PubMed · 16683851

Qdot nanobarcodes for multiplexed gene expression analysis.

Abstract

We report a quantum dot (Qdot) nanobarcode-based microbead random array platform for accurate and reproducible gene expression profiling in a high-throughput and multiplexed format. Four different sizes of Qdots, with emissions at 525, 545, 565, and 585 nm are mixed with a polymer and coated onto the 8-mum-diameter magnetic microbeads to generate a nanobarcoded bead termed as QBeads. Twelve intensity levels for each of the four colors were used. Gene-specific oligonucleotide probes are conjugated to the surface of each spectrally nanobarcoded bead to create a multiplexed panel, and biotinylated cRNAs are generated from sample total RNA and hybridized to the gene probes on the microbeads. A fifth streptavidin Qdot (655 nm or infrared Qdot) binds to biotin on the cRNA, acting as a quantification reporter. Target identity was decoded based on spectral profile and intensity ratios of the four coding Qdots (525, 545, 565, and 585 nm). The intensity of the 655 nm Qdot reflects the level of biotinylated cRNA captured on the beads and provides the quantification for the corresponding target gene. The system shows a sensitivity of < or =10(4) target molecules detectable with T7 amplification, a level that is better than the 10(5) number achievable with a high-density microarray system, and approaching the 10(3)-10(4) level usually observed for quantitative PCR (qPCR). The QBead nanobarcode system has a dynamic range of 3.5 logs, better than the 2-3 logs observed on various microarray platforms. The hybridization reaction is performed in liquid phase and completed in 1-2 hours, at least 1 order of magnitude faster than microarray-based hybridizations. Detectable fold change is lower than 1.4-fold, showing high precision even at close to single copy per cell level. Reproducibility for this proof-of-concept study approaches that of Affymetrix GeneChip microarray, with an R(2) value between two repeats at 0.984, and interwell CV around 5%. In addition, it provides increased flexibility, convenience, and cost-effectiveness in comparison to conventional gene expression profiling methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Scott Eastman, Weiming Ruan, Michael Doctolero, Rachel Nuttall, Gianfranco de Feo, Jennifer S Park, Julia S F Chu, Patrick Cooke, Joe W Gray, Song Li, Fanqing Frank Chen. 2006. Qdot nanobarcodes for multiplexed gene expression analysis.. https://doi.org/10.1021/nl060795t

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience.

BACKGROUND AND PURPOSE: In our clinic a QA program for IMRT verification, fully based on dosimetric measurements with electronic portal imaging devices (EPID), has been running for over 3 years. The program includes a pre-treatment dosimetric check of all IMRT fields. During a complete treatment simulation at the linac, a portal dose image (PDI) is acquired with the EPID for each patient field and compared with a predicted PDI. In this paper, the results of this pre-treatment procedure are analysed, and intercepted errors are reported. An automated image analysis procedure is proposed to limit the number of fields that need human intervention in PDI comparison. MATERIALS AND METHODS: Most of our analyses are performed using the gamma index with 3% local dose difference and 3mm distance to agreement as reference values. Scalar parameters are derived from the gamma values to summarize the agreement between measured and predicted 2D PDIs. Areas with all pixels having gamma values larger than one are evaluated, making decisions based on clinically relevant criteria more straightforward. RESULTS: In 270 patients, the pre-treatment checks revealed four clinically relevant errors. Calculation of statistics for a group of 75 patients showed that the patient-averaged mean gamma value inside the field was 0.43 +/- 0.13 (1SD) and only 6.1 +/- 6.8% of pixels had a gamma value larger than one. With the proposed automated image analysis scheme, visual inspection of images can be avoided in 2/3 of the cases. CONCLUSION: EPIDs may be used for high accuracy and high resolution routine verification of IMRT fields to intercept clinically relevant dosimetric errors prior to the start of treatment. For the majority of fields, PDI comparison can fully rely on an automated procedure, avoiding excessive workload.

Electronic Data Processing↗

The emergence of radiofrequency identification tags: applications in surgery.

Radiofrequency identification (RFID) is a wireless method of automatic identification. Currently, RFID tags are emerging into our environment in many aspects of our lives. Applications are being developed in a variety of fields, including health care. Aspects of surgical care will lend themselves to this approach. This technology could provide large amounts of data that not only carry the promise of improving health care, but also may have an impact on personal aspects of our daily lives. Each of us must become familiar with the risks and benefits of RFID use.

Electronic Data Processing↗