PubMed Health⌕ Search

PubMed · 16683956

Detection of left ventricle function from a magnetically levitated impeller behavior.

Abstract

The magnetically levitated (Mag-Lev) centrifugal rotary blood pump (CRBP) with two-degrees-of-freedom active control is promising for safe and long-term support of circulation. In this study, Mag-Lev CRBP controllability and impeller behavior were studied in the simulated heart failure circulatory model. A pneumatically driven pulsatile blood pump (Medos VAD [ventricular assist device]-54 mL) was used to simulate the left ventricle (LV). The Mag-Lev CRBP was placed between the LV apex and aortic compliance tank simulating LV assistance. The impeller behavior in five axes (x, y, z, theta, and phi) was continuously monitored using five eddy current sensors. The signals of the x- and y-axes were used for feedback active control, while the behaviors of the other three axes were passively controlled by the permanent magnets. In the static mock circuit, the impeller movement was controlled to within +/-10-+/-20 microm in the x- and y-axes, while in the pulsatile circuit, LV pulsation was modulated in the impeller movement with the amplitude being 2-22 microm. The amplitude of impeller movement measured at 1800 rpm with the simulated failing heart (peak LV pressure [LVP] = 70 mm Hg, mean aortic pressure [AoP(mean)] = 55 +/- 20 mm Hg, aortic flow = 2.7 L/min) was 12.6 microm, while it increased to 19.2 microm with the recovered heart (peak LVP = 122 mm Hg, AoP(mean) = 100 +/- 20 mm Hg, aortic flow = 3.9 L/min). The impeller repeated the reciprocating movement from the center of the pump toward the outlet port with LV pulsation. Angular rotation (theta, phi) was around +/-0.002 rad without z-axis displacement. Power requirements ranged from 0.6 to 0.9 W. Five-axis impeller behavior and Mag-Lev controller stability were demonstrated in the pulsatile mock circuit. Noncontact drive and low power requirements were shown despite the effects of LV pulsation. The impeller position signals in the x- and y-axes reflected LV function. The Mag-Lev CRBP is effective not only for noncontact low power control of the impeller, but also for diagnosis of cardiac function noninvasively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hideo Hoshi, Junichi Asama, Chikara Hara, Wataru Hijikata, Tadahiko Shinshi, Akira Shimokohbe, Setsuo Takatani. 2006. Detection of left ventricle function from a magnetically levitated impeller behavior.. https://doi.org/10.1111/j.1525-1594.2006.00229.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Left-ventricle myocardium segmentation using a coupled level-set with a priori knowledge.

This paper presents a coupled level-set segmentation of the myocardium of the left ventricle of the heart using a priori information. From a fast marching initialisation, two fronts representing the endocardium and epicardium boundaries of the left ventricle are evolved as the zero level-set of a higher dimension function. We introduce a novel and robust stopping term using both gradient and region-based information. The segmentation is supervised both with a coupling function and using a probabilistic model built from training instances. The robustness of the segmentation scheme is evaluated by performing a segmentation on four unseen data-sets containing high variation and the performance of the segmentation is quantitatively assessed.

Heart Ventricles↗

Left ventricular assist system through the left ventricle for acute myocardial infarction: report of a case.

A 49-year-old man, who had suffered from acute myocardial infarction due to left main trunk occlusion, developed cardiogenic shock and was successfully treated with an implantation of a left ventricular assist system with left ventricular apical drainage. At present he is awaiting a heart transplant at approximately 485 days since the operation. The timely application of a left ventricular assist system before the development of multiple organ failure is thus considered to be effective for patients demonstrating acute myocardial infarction with cardiogenic shock.

Heart Ventricles↗