PubMed HealthSearch

PubMed · 1672182

High-frequency ventilation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1991-03-23. High-frequency ventilation.. https://pubmed.ncbi.nlm.nih.gov/1672182/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dynamic lung inflation during high frequency oscillation in neonates.

The effects of high frequency oscillation (HFO) on dynamic lung inflation were examined in 22 neonates ventilated for respiratory disease. HFO was combined with conventional ventilation and a series of frequencies from 2-25 Hz was tested. Dynamic lung inflation was measured using a jacket plethysmograph which was converted to a measure of alveolar pressure using the compliance of the respiratory system obtained during conventional ventilation. The results showed an increase in dynamic lung inflation with frequency such that volume increased by 0.4 ml for each increase of 10 Hz. Alveolar pressure increased by 1.2 cm H2O for each increase of 10 Hz. Dynamic lung inflation also increased with increased volumes of oscillation.

High-Frequency Ventilation

[High frequency "bubble" oscillation ventilation in the neonatal period].

The authors tested their own high frequency, oscillation, "bubble" ventilator on a model of neonatal lungs in vitro and in vivo. They used the effect of oscillations which develop when through fluid (in vivo water) a mixture of air is bubbled and which can be, if the expiration tube is sufficiently rigid, transmitted back into the lungs. If the CPAP circuit is suitably arranged, it can ensure an adequate exchange of blood gases. The authors found marked changes in the amplitude of pressure oscillations as well as of the frequency in relation to the shape of the ending beneath the fluid surface (greatest when a funnel with a 30 mm diameter and 90 degree angle in relation to a normal line projected on the water surface is used). They found that the compliance (C) has no substantial effect on the amplitude nor on the frequency of oscillations. The mentioned bubble system approached as to its efficiency the commercial oscillation ventilator Stephen 3000 SFH and was used in the therapy of respiratory failure in three neonates with body weights of 1250-2700 g. The authors conclude that high frequency oscillation "bubble" ventilation is a cheap, safe and highly effective therapy which can be used in any department providing care of neonates even during transport.

High-Frequency Ventilation