Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomography.

Abstract

BACKGROUND: There are few dual X-ray absorptiometry (DXA) studies on periacetabular bone density changes after cup implantation. This study was designed to analyze the load-transfer mechanism and stress pattern of periacetabular cortical and cancellous bone after implantation of a ihemispherical titanium alloy press-fit cup with alumina-alumina pairing in vivo. We introduced a novel method of computed tomography (CT)-assisted osteodensitometry. METHOD: We investigated 26 hips (26 patients) with osteoarthritis using conventional sequential CT examinations performed within the first 10 days after implantation, and after a mean period of 1.1 years postoperatively. Bone density of full, cancellous and cortical bone (mgCaHA/mL) was measured. RESULTS: At the time of follow-up, the mean bone density values of the cortical bone cranial to the cup increased by 3.6% (p = 0.03) while the cancellous bone density decreased by 18%. Cancellous bone loss was greater in the region ventral to the cup (-35%) than in the dorsal region (-30%). Cortical bone density decreased ventral to the cup (-6.4%). All these changes were statistically significant. The bone density changes in the dorsal cortical region were not significant. INTERPRETATION: The method presented is an excellent tool for detailed measurement of bone density changes around the cup after total hip arthroplasty, and allows a thorough assessment of stress shielding phenomena in vivo. The hemispherical titanium alloy press-fit cup is a rigid implant which stress shields cancellous bone and enhances load transfer to the cranial cortical bone. Further investigations will demonstrate the impact these factors have on the long-term results of the implant, and may allow a type-related predictable prognosis of the longevity of the prosthesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lutz Arne Mueller, Alexander Kress, Tobias Nowak, David Pfander, Rocco Paolo Pitto, Raimund Forst, Rainer Schmidt. 2006. Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomography.. https://doi.org/10.1080/17453670610046299

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗