PubMed Health⌕ Search

PubMed · 16820424

Detecting potential labeling errors in microarrays by data perturbation.

Abstract

MOTIVATION: Classification is widely used in medical applications. However, the quality of the classifier depends critically on the accurate labeling of the training data. But for many medical applications, labeling a sample or grading a biopsy can be subjective. Existing studies confirm this phenomenon and show that even a very small number of mislabeled samples could deeply degrade the performance of the obtained classifier, particularly when the sample size is small. The problem we address in this paper is to develop a method for automatically detecting samples that are possibly mislabeled. RESULTS: We propose two algorithms, a classification-stability algorithm and a leave-one-out-error-sensitivity algorithm for detecting possibly mislabeled samples. For both algorithms, the key structure is the computation of the leave-one-out perturbation matrix. The classification-stability algorithm is based on measuring the stability of the label of a sample with respect to label changes of other samples and the version of this algorithm based on the support vector machine appears to be quite accurate for three real datasets. The suspect list produced by the version is of high quality. Furthermore, when human intervention is not available, the correction heuristic appears to be beneficial.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrea Malossini, Enrico Blanzieri, Raymond T Ng. 2006-07-04. Detecting potential labeling errors in microarrays by data perturbation.. https://doi.org/10.1093/bioinformatics%2Fbtl346

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗