PubMed · 16825749
Fast, multiple optimizations of quadratic dose objective functions in IMRT.
Abstract
Inverse treatment planning for intensity-modulated radiotherapy may include time consuming, multiple minimizations of an objective function. In this paper, methods are presented to speed up the process of (repeated) minimization of the well-known quadratic dose objective function, extended with a smoothing term that ensures generation of clinically acceptable beam profiles. In between two subsequent optimizations, the voxel-dependent importance factors of the quadratic terms will generally be adjusted, based on an intermediate plan evaluation. The objective function has been written in matrix-vector format, facilitating the use of a recently published, fast quadratic minimization algorithm, instead of commonly applied gradient-based methods. This format also reduces the calculation time in between subsequent minimizations, related to adjustment of the voxel-dependent importance factors. Sparse matrices are used to limit the required amount of computer memory. For three patients, comparisons have been made with a gradient method. Mean speed improvements of up to a factor of 37 have been achieved.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Sebastiaan Breedveld, Pascal R M Storchi, Marleen Keijzer, Ben J M Heijmen. 2006-07-06. Fast, multiple optimizations of quadratic dose objective functions in IMRT.. https://doi.org/10.1088/0031-9155%2F51%2F14%2F019
Cite the original work for its findings. Save a collection to share your selection of sources.