PubMed Health⌕ Search

PubMed · 16844964

Multiparametric cell cycle analysis by automated microscopy.

Abstract

Cell cycle analysis using flow cytometry (FC) to measure cellular DNA content is a common procedure in drug mechanism of action studies. Although this technique lends itself readily to cell lines that grow in suspension, adherent cell cultures must be resuspended in a cumbersome and potentially invasive procedure that normally involves trypsinization and mechanical agitation of monolayer cultures. High-content analysis (HCA), an automated microscopy-based technology, is well suited to analysis of monolayer cell cultures but provides intrinsically less accurate determination of cellular DNA content than does FC and thus is not the method of choice for cell cycle analysis. Using Cellomics's ArrayScan reader, the authors have developed a 4-color multiparametric HCA approach for cell cycle analysis of adherent cells based on detection of DNA content (4,6-diamidino-2-phenylindole [DAPI] fluorescence), together with the known cell cycle markers bromo-2-deoxyuridine (BrdU) incorporation, cyclin B1 expression, and histone H3 (Ser28) phosphorylation within a single cell population. Considering all 4 markers together, a reliable and accurate quantification of cell cycle phases was possible, as compared with flow cytometric analysis. Using this assay, specific cell cycle blocks induced by treatment with thymidine, paclitaxel, or nocodazole as test drugs were easily monitored in adherent cultures of U-2 OS osteosarcoma cells.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fabio Gasparri, Paolo Cappella, Arturo Galvani. 2006-07-14. Multiparametric cell cycle analysis by automated microscopy.. https://doi.org/10.1177/1087057106289406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characteristics of the m2000 automated sample preparation and multiplex real-time PCR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

We evaluated a new real-time PCR-based prototype assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae developed by Abbott Molecular Inc. This assay is designed to be performed on an Abbott m2000 real-time instrument system, which consists of an m2000sp instrument for sample preparation and an m2000rt instrument for real-time PCR amplification and detection. The limit of detection of this prototype assay was determined to be 20 copies of target DNA for both C. trachomatis and N. gonorrhoeae, using serially diluted linearized plasmids. No cross-reactivity could be detected when 55 nongonococcal Neisseria isolates and 3 non-C. trachomatis Chlamydia isolates were tested at 1 million genome equivalents per reaction. Concordance with the Roche Amplicor, BDProbeTec ET, and Gen-Probe APTIMA Combo 2 tests was assessed using unlinked/deidentified surplus clinical specimens previously analyzed with these tests. For C. trachomatis, concordance for positive results ranged from 93.7% to 100%, while concordance for negative results ranged from 98.2% to 100%. For N. gonorrhoeae, concordance for positive and negative results ranged from 91.4% to 100% and 99.3% to 100%, respectively. A workflow analysis of the prototype assay was conducted to obtain information on throughput under laboratory conditions. At 48 samples/run, the time to first result for both C. trachomatis and N. gonorrhoeae was 4.5 h. A total of 135 patient specimens could be analyzed in 8.9 h, with 75 min of hands-on time. This study demonstrated the technical and clinical feasibility of the new Abbott real-time PCR C. trachomatis/N. gonorrhoeae assay.

Automation↗

Pronase-immobilized enzyme reactor: an approach for automation in glycoprotein analysis by LC/LC-ESI/MSn.

An automated analytical approach is proposed for simultaneous characterization of glycan and peptide moieties in pronase-generated glycopeptides. The proposed method is based on the use of a new pronase-immobilized enzyme reactor for the on-line rapid digestion of the target glycoprotein. By coupling the bioreactor to a Hypercarb chromatographic trap column, on-line selective glycopeptide enrichment prior to normal-phase liquid chromatography-mass spectrometry was obtained. A detailed study was carried out for integration and automation of each phase of the proposed analytical procedure. On-line digestion allowed extensive cleavage of the model protein (ribonuclease B), yielding to glycopeptides with peptide moieties up to eight amino acids, carrying the Man5-Man9 N-glycans each, selectively resolved on an Amide-80 column. The use of a linear ion trap instrument resulted in efficient ion capture and led to MS3 acquisition times and spectra quality similar to those for MS2, allowing the unambiguous identification of glycan (MS2) and peptide (MS3) sequences. The proposed procedure reduces the glycoprotein analysis time from approximately 3 days, as in most of the traditional off-line methods, to approximately 1 h.

Automation↗

An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates.

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for terbinafine quantification in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deepwell plates. Terbinafine and the internal standard (IS) N-methyl-1-naphthalenemethylamine were extracted from human plasma by LLE, using a mixture of methyl t-butyl ether (MTBE)-hexane (70:30, v/v) as the organic solvent. All liquid transfer steps, including preparation of calibration standards and quality control samples, as well as the addition of the IS, were performed automatically by using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of a reconstitution solution. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The method had a very short sample preparation time and a chromatographic run time of 2.2 min. It was proved to have excellent sensitivity, specificity, accuracy as well as inter- and intraday precision for the quantification of terbinafine in human plasma. The calibration curve was linear for the range of concentrations 5.0-2000.0 ng/mL. The proposed method was applied to the rapid and reliable determination of terbinafine in a bioequivalence study after per os administration of 250 mg tablet formulations of terbinafine.

Automation↗