Pumping test evaluation of stream depletion parameters.

Abstract

Descriptions are given of a pumping test and a corresponding analysis that permit calculation of all five hydrogeological parameters appearing in the Hunt (2003) solution for stream depletion caused by ground water abstraction from a well beside a stream. This solution assumes that flow in the pumped aquifer is horizontal, flow in the overlying aquitard or system of aquitards is vertical, and the free surface in the top aquitard is allowed to draw down. The definition of an aquitard in this paper is any layer with a vertical hydraulic conductivity much lower than the horizontal hydraulic conductivity of the pumped aquifer. These "aquitards" may be reasonably permeable layers but are distinguished from the pumped aquifer by their hydraulic conductivity contrast. The pumping test requires a complete set of drawdown measurements from at least one observation well. This well must be deep enough to penetrate the pumped aquifer, and pumping must continue for a sufficient time to ensure that depleted streamflow becomes a significant portion of the well abstraction rate. Furthermore, two of the five parameters characterize an aquitard that overlies the pumped aquifer, and values for these parameters are seen to be dependent upon the initial water table elevation in the aquitard. The field test analyzed herein used a total of eight observation wells screened in the pumped aquifer, and measurements from these wells gave eight sets of parameters that are used in a sensitivity analysis to determine the relative importance of each parameter in the stream depletion calculations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hilary K Lough, Bruce Hunt. Pumping test evaluation of stream depletion parameters.. https://doi.org/10.1111/j.1745-6584.2006.00212.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Salinimicrobium molybdatiresistens sp. nov., a novel molybdate-resistant and selenite-reducing bacterium isolated from river silt.

Strain TH3T was isolated from the river bottom silt collected in Hengshui, Hebei Province, China. The bacterium is a yellow-pigmented, rod-shaped, Gram-staining negative and aerobic organism. It was able to grow between 10 and 37 °C (optimum 30 °C), at pH values from 5.0 to 9.0 (optimum pH 7.0), and tolerated NaCl concentrations ranging from 0 to 13% (w/v, optimum 2%). The 16 S rRNA gene sequence of strain TH3T was found to be most closely related to Salinimicrobium sediminilitoris ASW11-47T (99.7%). Nevertheless, genome comparison revealed the relatedness indices below species delineation thresholds: digital DNA-DNA hybridization was 49.7%, and average nucleotide identity was 93.2%, and average amino acid identity was 94.2% compared to Salinimicrobium sediminilitoris ASW11-47T. Strain TH3T had a genome size of 3.7 Mb and a DNA G + C content of 41.0%. The major fatty acids observed for strain TH3T (≥ 5%) were iso-C14:0, iso-C15:0, anteiso-C15:0, iso-C16:0, iso-C16:0 3-OH, iso-C17:0 3-OH, and summed feature 3. The polar lipid composition included phosphatidylethanolamine, one unidentified phospholipid, two aminolipids, along with five unknown lipids. The sole respiratory quinone in strain TH3T was menaquinone-6. In addition, strain TH3T was highly resistant to molybdate (500 mM) and selenite (20 mM), and could completely reduce 1 mM selenite to red elemental SeNPs within 3 d. Strain TH3T contains several putative selenite-reducing genes, including sodA, serA, serC, cysH, deoC, tktA, and pdhC. Based on polyphasic characterization, strain TH3T was found to be a novel species in the genus Salinimicrobium, and the proposed name is Salinimicrobium molybdatiresistens sp. nov. The type strain is TH3T (= GDMCC 1.3399T = JCM 35713T).

Rivers↗

Microbial genomic database of the Yangtze River, the third-longest river on Earth.

Microbes play an important role in mediating the nutrient cycling in the river ecosystem as a hotspot for biogeochemical processes. Due to scattered sampling efforts, however, there is a lack of a systematic study of the diversity of prokaryotic genomes in the Yangtze River, the third longest river on Earth. Here, we collected 602 metagenomic datasets of water, sediment and riparian soil samples spanning the Upper, Middle, and Lower basins of the Yangtze River over a 6,300 km continuum. We reconstructed 8,110 qualified genomes represented by 927 species-level genomes at the 95% ANI threshold, spanning 31 bacterial and five archaeal phyla. We further showed that more than half of these species (61.3% ~ 82.4%) were novel according to the genomic comparison against the curated databases, greatly expanding the known diversity of river prokaryotes. This dataset depicts an overview of microbial genomic diversity in the Yangtze River and provides a resource for in-depth investigation of metabolic potential, ecology, and evolution of riverine microbiomes.

Rivers↗

Irrigation efficiency and quality of irrigation return flows in the Ebro River Basin: an overview.

The review analysis of twenty two irrigation efficiency (IE) studies carried out in the Ebro River Basin shows that IE is low (average IE)(avg)(= 53%) in surface-irrigated areas with high-permeable and shallow soils inadequate for this irrigation system, high (IE)(avg)(= 79%) in surface-irrigated areas with appropriate soils for this system, and very high (IE)(avg)(= 94%) in modern, automated and well managed sprinkler-irrigated areas. The unitary salt (total dissolved solids) and nitrate loads exported in the irrigation return flows (IRF) of seven districts vary, depending on soil salinity and on irrigation and N fertilization management, between 3-16 Mg salt/ha x year and 23-195 kg NO)(3) (-)-N/ha x year, respectively. The lower nitrate loads exported from high IE districts show that a proper irrigation design and management is a key factor to reduce off-site nitrogen pollution. Although high IE's also reduce off-site salt pollution, the presence of salts in the soil or subsoil may induce relatively high salt loads (>or=14 Mg/ha x year) even in high IE districts. Two important constrains identified in our revision were the short duration of most surveys and the lack of standards for conducting irrigation efficiency and mass balance studies at the irrigation district level. These limitations {emphasize the need for the establishment of a permanent and standardized network of drainage monitoring stations for the appropriate off-site pollution diagnosis and control of irrigated agriculture.

Rivers↗