CONTEXT: Proper specimen identification and labeling is a critical preanalytic step in pretransfusion compatibility testing. OBJECTIVE: To gather baseline data for specimen mislabeling, specifically targeting major mislabeling events, and to design and implement a plan of corrective action. DESIGN: All mislabeled specimens received by the transfusion service for a type and screen were recorded and classified into minor and major mislabeling categories. Major mislabeling events were tracked by origin of the specimen. Locations with a high proportion of major mislabeling were given timely feedback (within 1 week) of the events as they arose. SETTING: A university hospital. MAIN OUTCOME MEASURES: The incidence of major mislabeling. RESULTS: The incidence of mislabeling in the transfusion service was 0.5% (243/49 955) during 21 months of data collection. Of these mislabeling events, 47% were classified as major events (unlabeled, mismatched specimen/ requisition, ABO/Rh result on current specimen not matching historical record on file). The emergency department accounted for a high proportion of these major mislabeling events. After the intervention of providing weekly feedback to emergency department staff, their contribution to major mislabeling fell from 47% in 1 year (23/49) to 14% (4/29) in the subsequent 3 quarters. CONCLUSIONS: Collecting and trending data on mislabeled samples with timely feedback to patient care areas can change phlebotomy practice and reduce specimen mislabeling.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Karen Quillen, Kate Murphy. 2006. Quality improvement to decrease specimen mislabeling in transfusion medicine.. https://doi.org/10.5858/2006-130-1196-qitdsm

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Increasing patient safety and efficiency in transfusion therapy using formal process definitions.

The administration of blood products is a common, resource-intensive, and potentially problem-prone area that may place patients at elevated risk in the clinical setting. Much of the emphasis in transfusion safety has been targeted toward quality control measures in laboratory settings where blood products are prepared for administration as well as in automation of certain laboratory processes. In contrast, the process of transfusing blood in the clinical setting (ie, at the point of care) has essentially remained unchanged over the past several decades. Many of the currently available methods for improving the quality and safety of blood transfusions in the clinical setting rely on informal process descriptions, such as flow charts and medical algorithms, to describe medical processes. These informal descriptions, although useful in presenting an overview of standard processes, can be ambiguous or incomplete. For example, they often describe only the standard process and leave out how to handle possible failures or exceptions. One alternative to these informal descriptions is to use formal process definitions, which can serve as the basis for a variety of analyses because these formal definitions offer precision in the representation of all possible ways that a process can be carried out in both standard and exceptional situations. Formal process definitions have not previously been used to describe and improve medical processes. The use of such formal definitions to prospectively identify potential error and improve the transfusion process has not previously been reported. The purpose of this article is to introduce the concept of formally defining processes and to describe how formal definitions of blood transfusion processes can be used to detect and correct transfusion process errors in ways not currently possible using existing quality improvement methods.

Blood Group Incompatibility↗

Error management of emergency transfusions: a surveillance system to detect safety risks in day to day practice.

Acute hemolysis due to AB0-incompatibility caused by transfusion of red blood cell concentrates (RBCC) to the wrong recipient is one of the major causes of transfusion-related death. As part of our policy to improve quality and safety in emergency transfusion, we have developed a standardized surveillance system for supplying RBCC in emergency situations. This surveillance system involves the implementation of a standardized set of basic data transmitted from the requesting unit to the blood bank by phone and a scoring system to check for compliance with guidelines and errors in daily routines. Communication deficiencies and delayed pretransfusion sampling were the most common errors.

Blood Group Incompatibility↗