PubMed Health⌕ Search

PubMed · 16936137

Retinal microscotomas revealed with adaptive-optics microflashes.

Abstract

PURPOSE: To develop a sensitive psychophysical test for detecting visual defects such as microscotomas. METHODS: Frequency-of-seeing curves were measured with 0.75' and 7.5' spots. On each trial, from 0 to 4 stimuli were randomly presented at any of eight equally spaced loci 0.5 degrees from fixation. By correcting the aberrations of the eye, adaptive optics produced retinal images of the 0.75' spot that were 3.0 microm wide at half height, small enough to be almost entirely confined within the typical cone diameter at this eccentricity. Data were collected from a patient with deuteranopia (AOS1) whose retina, imaged with adaptive optics, suggested that approximately 30% of his cones were missing or abnormal. Patients with protanomalous trichromacy (1 subject), deuteranopia (1 subject), and trichromacy (5 subjects) served as controls (all had normal cone density and complete cone mosaics). Psychophysical results were modeled by a Monte Carlo simulation incorporating measured properties of the cone mosaic. RESULTS: Frequency-of-seeing curves for AOS1 obtained with 0.75' spots showed lower asymptote, slope, and sensitivity than for controls. The 7.5' results showed that these differences were the result of the small spot size, which on some trials was confined mostly to the locus of the putatively missing cones. A two-parameter model satisfactorily described the data and was highly sensitive to the proportion of missing cones simulated. CONCLUSIONS: Adaptive-optics microperimetry is a powerful psychophysical test for assessing the loss of neural elements, even in retinas that appear otherwise normal in standard clinical tests. This technique may prove useful in estimating the proportion of missing cones in different patients and in detecting other visual losses such as those associated with glaucoma.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Walter Makous, Joseph Carroll, Jessica I Wolfing, Julianna Lin, Nathan Christie, David R Williams. 2006. Retinal microscotomas revealed with adaptive-optics microflashes.. https://doi.org/10.1167/iovs.05-1195

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel homogenous time-resolved fluorometric RT-PCR assays for quantification of PSA and hK2 mRNAs in blood.

OBJECTIVES: The purpose of this study was to design, validate, and optimize internally standardized real-time quantitative RT-PCR assays and to identify and avoid problems with assay reliability and examine the impact of an exogenous internal standard. DESIGN AND METHODS: The model system consisted of internally standardized quantitative real-time RT-PCR assays specific for PSA and hK2 mRNA based on time-resolved fluorometric detection of lanthanide chelates. RESULTS: Reproducibility was best when large copy numbers (>5000 per milliliter blood) were analyzed. Addition of an exogenous target-mimicking internal standard had no significant effect on the reproducibility of the method, but increased the calculated copy numbers by an average of 2-fold. CONCLUSIONS: We developed an internally standardized, specific and reproducible real-time RT-PCR analysis method for PSA and hK2 mRNA in circulating cells in the bloodstream. Both PSA and hK2 assays are sufficiently sensitive to detect two LNCaP cells per milliliter whole blood.

False Positive Reactions↗