No-reference image quality metrics for structural MRI.

Abstract

Neuroimagery must be visually checked for unacceptable levels of distortion prior to processing. However, inspection is time-consuming, unreliable for detecting subtle distortions and often subjective. With the increasing volume of neuroimagery, objective measures of quality are needed in order to automate screening. To address this need, we have assessed the effectiveness of no-reference image quality measures, which quantify quality inherent to a single image. A data set of 1001 magnetic resonance images (MRIs) recorded from 143 subjects was used for this evaluation. The MRI images were artificially distorted with two levels of either additive Gaussian noise or intensity nonuniformity created from a linear model. A total of 239 different quality measures were defined from seven overall families and used to discriminate images for the type and level of distortion. Analysis of Variance identified two families of quality measure that were most effective: one based on Natural Scene Statistics and one originally developed to measure distortion caused by image compression. Measures from both families reliably discriminated among undistorted images, noisy images, and images distorted by intensity nonuniformity. The best quality measures were sensitive only to the distortion category and were not significantly affected by other factors. The results are encouraging enough that several quality measures are being incorporated in a real world MRI test bed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeffrey P Woodard, Monica P Carley-Spencer. 2006. No-reference image quality metrics for structural MRI.. https://doi.org/10.1385/ni%3A4%3A3%3A243

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗