Multi-Q: a fully automated tool for multiplexed protein quantitation.

Abstract

The iTRAQ labeling method combined with shotgun proteomic techniques represents a new dimension in multiplexed quantitation for relative protein expression measurement in different cell states. To expedite the analysis of vast amounts of spectral data, we present a fully automated software package, called Multi-Q, for multiplexed iTRAQ-based quantitation in protein profiling. Multi-Q is designed as a generic platform that can accommodate various input data formats from search engines and mass spectrometer manufacturers. To calculate peptide ratios, the software automatically processes iTRAQ's signature peaks, including peak detection, background subtraction, isotope correction, and normalization to remove systematic errors. Furthermore, Multi-Q allows users to define their own data-filtering thresholds based on semiempirical values or statistical models so that the computed results of fold changes in peptide ratios are statistically significant. This feature facilitates the use of Multi-Q with various instrument types with different dynamic ranges, which is an important aspect of iTRAQ analysis. The performance of Multi-Q is evaluated with a mixture of 10 standard proteins and human Jurkat T cells. The results are consistent with expected protein ratios and thus demonstrate the high accuracy, full automation, and high-throughput capability of Multi-Q as a large-scale quantitation proteomics tool. These features allow rapid interpretation of output from large proteomic datasets without the need for manual validation. Executable Multi-Q files are available on Windows platform at http://ms.iis.sinica.edu.tw/Multi-Q/.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wen-Ting Lin, Wei-Neng Hung, Yi-Hwa Yian, Kun-Pin Wu, Chia-Li Han, Yet-Ran Chen, Yu-Ju Chen, Ting-Yi Sung, Wen-Lian Hsu. 2006. Multi-Q: a fully automated tool for multiplexed protein quantitation.. https://doi.org/10.1021/pr060132c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of phenolic metabolites of polycyclic aromatic hydrocarbons in human urine as their pentafluorobenzyl ether derivatives using liquid chromatography-tandem mass spectrometry.

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental contaminants, and a number of them are carcinogenic. One approach for measuring exposure to them is to determine the concentrations of metabolites in urine. The pyrene metabolite 1-hydroxypyrene has been used as a biomarker for exposure in numerous studies. However, determination of exposure to several PAHs may be advantageous, since the relative amounts may vary depending upon the exposure source. We developed a liquid chromatography-tandem mass spectrometry method for the determination of phenolic metabolites of naphthalene, fluorene, phenanthrene, and pyrene in human urine. Following enzymatic cleavage of the glucuronide and sulfate conjugates, the phenolic metabolites are extracted from urine and converted to pentafluorobenzyl ethers. These derivatives greatly enhance the sensitivity of detection by atmospheric pressure chemical ionization in the negative ion mode. Lower limits of quantitation range from 0.01 to 0.5 ng/mL. Stable isotope-labeled internal standards were synthesized or obtained commercially. Data on urinary excretion of several PAH metabolites in urine of smokers and nonsmokers are presented.

Chromatography, Liquid↗

MicroSPE-nanoLC-ESI-MS/MS using 10-microm-i.d. silica-based monolithic columns for proteomics.

Silica-based monolithic capillary columns (25 cm x 10 microm i.d.) with integrated nanoESI emitters have been developed to provide high-quality and robust microSPE-nanoLC-ESI-MS analyses. The integrated nanoESI emitter adds no dead volume to the LC separation, allowing stable electrospray operation at flow rates of approximately 10 nL/min. In an initial application with a linear ion trap MS, we identified 5510 unique peptides that covered 1443 distinct Shewanella oneidensis proteins from a 300-ng tryptic digest sample in a single 4-h LC-MS/MS analysis. The use of an integrated monolithic ESI emitter provided enhanced resistance to clogging and provided good run-to-run reproducibility.

Chromatography, Liquid↗

Method validation for the analysis of 169 pesticides in soya grain, without clean up, by liquid chromatography-tandem mass spectrometry using positive and negative electrospray ionization.

Part of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL(-1)) into the LC-MS/MS system. Linearity, r(2) of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r(2)> or =0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL(-1), corresponding with pesticide concentrations in soya bean extract of 2 or 5-200 microg kg(-1). Instrument LOD values generally were 0.1 or 0.25 ng mL(-1). Matrix effects were negligible for approximately 90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 microg kg(-1), six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 microg kg(-1) and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70-120%) and RSD (< or =20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.

Chromatography, Liquid↗