Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations.

Abstract

Correlation of the anatomical and functional information presented by single-photon emission computed tomography (SPECT) and computed tomography (CT) can aid in the decision-making process by enabling better localization and definition of organs and lesions and improving the precision of surgical biopsies. Technical developments over the past 20 years have led to the development of better software techniques for image fusion and, more recently, to the development of modern SPECT/CT systems. While image fusion techniques have been in clinical use for many years, the first commercial SPECT/CT system was only developed in 1999. Following the commercial success of PET/CT systems that employed multidetector CT (MDCT) scanners, there has been renewed interest in the development of comparable SPECT/CT systems. This has resulted in the development of a range of SPECT/CT devices varying from a simple CT add-on to a conventional SPECT system that can provide low-dose CT images to a full MDCT scanner integrated with a SPECT system. The advantages of combining SPECT with CT are numerous and are primarily due to the anatomic referencing and the attenuation correction capabilities of CT. Depending on system design, there are varying technical issues surrounding the different SPECT/CT devices, ranging from cost, radiation dose, planning, and siting requirements to system-specific issues such as table sag and CT artifacts due to patient motion. Motion artifacts should be less prevalent with the faster acquisition times of modern scanners, but are still problematic in the thorax and have not yet been fully resolved as they pertain to the use of CT data for cardiac attenuation correction. As this technology matures, we can expect to see a range of SPECT/CT devices available on the market that range from low-dose 1-4 slice inexpensive CT upgrades of conventional SPECT systems, to SPECT systems incorporating 64 or 128 slices CT scanners. The cost of the high-end CT scanners will exceed the cost of the SPECT scanner and hence the justification for such devices will be heavily dependent on clear demonstration of their value in clinical practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael K O'Connor, Brad J Kemp. 2006. Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations.. https://doi.org/10.1053/j.semnuclmed.2006.05.005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗