PubMed Health⌕ Search

PubMed · 16980684

Localization: conventional and CT simulation.

Abstract

Recent developments in imaging and computer power have led to the ability to acquire large three dimensional data sets for target localization and complex treatment planning for radiation therapy. Conventional simulation implies the use of a machine capable of the same mechanical movements as treatment units. Images obtained from these machines are essentially two dimensional with the facility to acquire a limited number of axial slices to provide patient contours and tissue density information. The recent implementation of cone beam imaging on simulators has transformed them into three dimensional imaging devices able to produce the data required for complex treatment planning. The introduction of computed axial tomography (CT) in the 1970s was a step-change in imaging and its potential use in radiotherapy was quickly realised. However, it remained a predominantly diagnostic tool until modifications were introduced to meet the needs of radiotherapy and software was developed to perform the simulation function. The comparability of conventional and virtual simulation has been the subject of a number of studies at different disease sites. The development of different cross sectional imaging modalities such as MRI and positron emission tomography has provided additional information that can be incorporated into the simulation software by image fusion and has been shown to aid in the delineation of tumours. Challenges still remain, particularly in localizing moving structures. Fast multislice scanning protocols freeze patient and organ motion in time and space, which may lead to inaccuracy in both target delineation and the choice of margins in three dimensions. Breath holding and gated respiration techniques have been demonstrated to produce four-dimensional data sets that can be used to reduce margins or to minimize dose to normal tissue or organs at risk. Image guided radiotherapy is being developed to address the interfraction movement of both target volumes and critical normal structures. Whichever method of localization and simulation is adopted, the role of quality control is important for the overall accuracy of the patient's treatment and must be adapted to reflect the networked nature of the process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G R Baker. 2006. Localization: conventional and CT simulation.. https://doi.org/10.1259/bjr%2F17748030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗