PubMed Health⌕ Search

PubMed · 16995793

Novel geometries for tissue-engineered tendonous collagen constructs.

Abstract

A promising approach to addressing the performance limitations of currently available mechanical and bioprosthetic heart valves lies in tissue engineering. Tissue-engineered valves should incorporate the complex microstructure of the native valves to mimic their unique mechanics. This would include a layered topology, mesh networks, and branched collagen fiber bundles. Our approach to heart valve tissue engineering is to develop the functional components of the aortic valve cusps separately in vitro and, once they are mature, integrate them into a composite valve structure. Here we report on our efforts to create more complex collagenous structures, suitable for heart valve tissue engineering. Collagen fiber bundles were fabricated using the principle of directed collagen gel contraction, using neonatal rat aortic smooth muscle cells and acid-soluble type I rat-tail tendon collagen. The collagen gels were cast into rectangular or branched wells with porous end holders that constrained the gels longitudinally but allowed contraction to occur transverse to the long axis. Pairs of such constructs were placed in direct contact with each other and cultured further to determine whether they integrated to form continuous tissue. After 6-8 weeks of culture, highly compacted and aligned collagen fiber bundles formed. Mechanical testing revealed that linear constructs (2 free ends) with an 8:1 aspect ratio were significantly stronger than similar constructs with an aspect ratio of 2:1 (mean +/- SD, 298 +/- 90 kPa vs. 152 +/- 49 kPa; p < .001). Branching reduced mechanical strength considerably. Constructs fabricated with 4 free ends were significantly weaker than constructs with 3 ends (31 +/- 32 kPa vs. 116 +/- 66 kPa; p < .003). Histologic images demonstrated the integration of the crossed collagen bundles, with a bonding strength of 2.1 +/- 1.1 g (0.02 N). We found that the geometry of the molds into which the collagen constructs are cast can greatly affect their mechanical strength: multibranched constructs were the weakest, and long, linear constructs were the strongest. We also found that integration of collagen constructs occurs in vitro and that the fabrication of a composite structure in vitro is probably feasible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yaling Shi, Lawrence Rittman, Ivan Vesely. 2006. Novel geometries for tissue-engineered tendonous collagen constructs.. https://doi.org/10.1089/ten.2006.12.2601

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Encapsulation of proteins in biodegradable polymeric microparticles using electrospray in the Taylor cone-jet mode.

Solvent extraction (or evaporation from a W(1)/O/W(2)-dispersion), coacervation, and spray drying methods are commonly employed to encapsulate protein drugs in polymeric microparticles for sustained delivery applications. To overcome the limitations of these methods, a novel electrospray method was developed to encapsulate a model protein drug-bovine serum albumin (BSA) in biodegradable polymeric microparticles and examine the feasibility of the process in not denaturing the protein. Microparticles of approximately 20 microm diameter with corrugated surfaces and smooth surfaces were observed by scanning electron microscope. Confocal laser scanning microscope images showed that BSA was distributed evenly in microparticles. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) was employed to investigate the protein integrity of BSA released from the polymer matrix after 38 days. No protein degradation was observed during the 38 days release. The secondary structure of released BSA was characterized by Fourier transform infrared (FTIR) and circular dichroism (CD), which suggested that the released BSA was almost identical to native BSA. The encapsulation efficiency could reach 76% by adjusting the amount of the additive Pluronic F127 and processing parameters. The release profile could be tailored by the fabrication process and the sustained release of BSA could endure for more than 1 month. More than 80% of the bioactivity of BSA (evaluated by BSA ELISA kit) could be maintained after releasing from polymer matrix. Findings of the present study demonstrate that this novel electrospray method is a promising approach to encapsulate bioactive materials such as proteins, enzymes, antibiotics, and DNA fragments in biodegradable polymeric particles.

Absorbable Implants↗

A novel poly(ethylene glycol)-fibrinogen hydrogel for tibial segmental defect repair in a rat model.

The aim of this study is to investigate regeneration in a segmental bone defect using a novel fibrinogen-based hydrogel material. The use of hydrogels made from poly(ethylene glycol) (PEG) conjugated to fibrinogen for this purpose may be better to conventional fibrin-based materials as it offers an additional degree of control over the structural characteristics and biodegradation of the material. At the same time, it maintains some of the inherent biofunctionality of the fibrinogen molecule. PEGylated fibrinogen hydrogels with various degrees of proteolytic resistance based on PEG and fibrinogen composition were designed for slow, intermediate, and fast biodegradation. The hydrogels were implanted into 7-mm segmental rat tibial defects without additional osteoinductive factors with the rationale that the ingrowth matrix will displace the normal fibrin clot while sustaining a similar healing effect for a longer duration. Histological and X-ray results confirmed that the extent and distribution of newly formed bone in the defect after 5 weeks strongly parallels the biodegradation pattern of the implanted material. When compared to nonunions in animals treated with the fast-degrading implants and untreated control animals, the rats implanted with the intermediate-degrading material exhibited osteoneogenesis. This data supports the hypothesis that the perseverance of the PEGylated fibrinogen material can be synchronized with the optimal healing characteristics of a segmental osseous defect and that the consequent sustained release of fibrinogen fragments facilitates the osteogenic response at the injury site. The PEGylated fibrinogen material may, therefore, be a highly efficacious material for promoting the healing of bone defects and especially nonunion fractures.

Absorbable Implants↗

Pores in synthetic nerve conduits are beneficial to regeneration.

Current opinion holds that pores in synthetic nerve guides facilitate nerve regeneration. Solid factual support for this opinion, however, is absent; most of the relevant studies assessed only morphological parameters and results have been contradictory. To evaluate the effect of pores, the rat sciatic nerve was either autografted or grafted with nonporous, macroporous (10-230 mum), and microporous (1-10 microm) biodegradable epsilon-caprolactone grafts. Twelve weeks later, the grafted nerves were resected, and the electrophysiological properties were determined in vitro. Subsequently midgraft-level sections were inspected, and peroneal nerve sections were evaluated morphometrically. Finally, the gastrocnemic and tibial muscle morphometrical properties were quantified. The microporous nerve graft performed much better than the nonporous and macroporous grafts with respect to most parameters: it was bridged by a free floating bundle that contained myelinated nerve fibers, there were more nerve fibers present distal to the graft, the electrophysiological response rate was higher, and the decrease in muscle cross-sectional area was markedly smaller. Hence, the present study demonstrates the beneficial effect of synthetic nerve guide pores on nerve regeneration, although with the caveat that not pores per se, but only small (1-10 microm) pores were effective.

Absorbable Implants↗