Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters.

Abstract

In this work a microflow structure, suitable for micro-FIA (micro flow injection analysis), will be described, evaluated and applied to real samples. Microchannels, the detector flow cell and input/output ports have been micromachined in silicon and sealed with anodically bonded Pyrex glass. The channels are defined by etching approximately 200 microm depth in silicon using a dry reactive ion etching (RIE) process. Optical windows integrated in the chip structure allow simple absorbance/transmission measurements to be made. The optical measurements were made using an LED as emitter (lambda=525 nm) and a photodiode as a detector. A Visual-Basic program has been developed to control an automatic burette, three-way solenoid valves and the data acquisition system. The micro-FIA for nitrite determination using the Griess-Ilosvay reaction has been implemented for the on-line monitoring of wastewater treatment plants (WWTPs). The multicommutation concept has been applied in order to enhance the mixing process inside the microsystem. Tandem streams of reagent and sample were generated and evaluated at different commutation frequencies. Two optimal frequencies, 400/200 ms and 150/450 ms, were found to be the most suitable ones. The first commutation ratio gave rise to wide linear working range (0-250 ppm), in spite of a high detection limit (0.35 ppm) and a low sensitivity (0.0041+/-0.0004 AU ppm-1). With the second ratio, the working linear range was smaller (0-50 ppm) but the detection limit (0.17 ppm) and the sensitivity (0.0091+/-0.0003 AU ppm-1) improved remarkably. Finally, real samples with a high nitrite concentration (0-1500 ppm) coming from a study of kinetic inhibition in the nitrification process at a WWTP has been analysed with the proposed micro-FIA system. The obtained results have allowed the corroboration of the model of inhibition by the nitrite ion with great exactitude.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

María del Mar Baeza, Nuria Ibanez-Garcia, Joan Baucells, Jordi Bartrolí, Julián Alonso. 2006-08-18. Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters.. https://doi.org/10.1039/b605043c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of the Agilent 2100 bioanalyzer for rapid and reproducible molecular typing of Streptococcus pneumoniae.

Restriction fragment length polymorphism (RFLP) analysis is an economic and fast technique for molecular typing but has the drawback of difficulties in accurately sizing DNA fragments and comparing banding patterns on agarose gels. We aimed to improve RFLP for typing of the important human pathogen Streptococcus pneumoniae and to compare the results with the commonly used typing techniques of pulsed-field gel electrophoresis and multilocus sequence typing. We designed primers to amplify a noncoding region adjacent to the pneumolysin gene. The PCR product was digested separately with six restriction endonucleases, and the DNA fragments were analyzed using an Agilent 2100 bioanalyzer for accurate sizing. The combined RFLP results for all enzymes allowed us to assign each of the 47 clinical isolates of S. pneumoniae tested to one of 33 RFLP types. RFLP analyzed using the bioanalyzer allowed discrimination between strains similar to that obtained by the more commonly used techniques of pulsed-field gel electrophoresis, which discriminated between 34 types, and multilocus sequence typing, which discriminated between 35 types, but more quickly and with less expense. RFLP of a noncoding region using the Agilent 2100 bioanalyzer could be a useful addition to the molecular typing techniques in current use for S. pneumoniae, especially as a first screen of a local population.

Autoanalysis↗

A three-armed trial of the ThinPrep Imaging System.

We compared the performance of the ThinPrep (TP) Imaging System (TIS) with manual reading of TP slides (TPM) and with manual reading of the paired conventional Pap smear (PS) in terms of sensitivity for and positive predictive value (PPV) of high-grade disease and productivity. The study consisted of 11,416 routine PS and paired TP slides as well as 103 confirmed abnormal TP slides. In terms of sensitivity for the detection of biopsy-confirmed high-grade disease, overall there was no statistically significant difference between TIS-screened TP (TPI) and TPM (81.1% vs. 86.8%). For the routine cases, TPI was significantly more sensitive than PS (73.4% vs. 57.8%). In terms of PPVs for the cytologic prediction of high-grade disease, there was no statistically, significant difference among TPI, TPM, and PS (75.6%, 73.9%, and 84.6%). For cytologic reports of possible high-grade disease, the PPVs were equivalent for TPI (45.0%) and TPM (37.0%) and there was no significant difference in PPVs between TPI and PS (61.3%). For TP slides, TIS screening showed a 27% productivity gain when compared with manual screening and a 54% productivity gain when compared with manual screening of PS slides. Use of TIS showed productivity benefits when compared with TPM and both productivity and sensitivity benefits over use of PS.

Autoanalysis↗