Lower oxygen saturation alarm limits decrease the severity of retinopathy of prematurity.

Abstract

PURPOSE: To determine whether lowering oxygen saturation alarm limits for infants at risk for retinopathy of prematurity (ROP) reduces its incidence and/or severity. METHODS: Oximetry alarm limits were lowered to 85% and 93% for all infants with a birth weight 1250 g or less and/or gestational age 28 weeks or less, and maintained until 32 weeks' postmenstrual age or until oxygen saturations were consistently greater than 93% in room air. The new policy was effective for infants born on or after June 1, 2003. ROP data were prospectively collected, and we compared the rate and severity of ROP in the year after the oximeter alarm policy change to the rates in the immediately preceding 3 years. RESULTS: In the year after the oximeter alarm limit policy change, 4 of 72 infants developed prethreshold ROP compared with 44 of 251 infants in the previous 3-year epoch (17.5% vs 5.6%, p=0.01). Similarly, only 6 of 144 eyes developed prethreshold ROP in the year after the policy change, compared with 84 of 502 in the previous 3 years (16.7% vs 4.2%, p=0.001). CONCLUSIONS: A simple change in oximeter alarm parameters in the first weeks of life for infants with a birth weight 1250 g or less may decrease the incidence of prethreshold ROP.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Deborah K Vanderveen, Theresa A Mansfield, Eric C Eichenwald. 2006. Lower oxygen saturation alarm limits decrease the severity of retinopathy of prematurity.. https://doi.org/10.1016/j.jaapos.2006.04.010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple teaching tool for training the pelvic organ prolapse quantification system.

The pelvic organ prolapse quantification (POPQ) system is currently the most common and specific system describing different prolapse stages. Nevertheless, its use is not yet accepted worldwide in routine care. Our aim was to develop a simple teaching tool for the POPQ system capable of simulating different stages of uterovaginal prolapse for use in medical education with hands on training. We constructed a moveable and flexible tool with an inverted Santa Claus' cap, which simulated the vaginal cuff and the tassel at the end representing the cervix. A wooden embroidery frame fixed the cap and served as the hymen, the reference point for all measurements. Inside the cap, we sewed buttons to define the anatomic landmark points Aa and Ap located 3 cm distal from the frame. After explaining the device to the students, we used the three-by-three grid for recording the quantitative description of the pelvic organ support. First, each student had to demonstrate a specific prolapse with his cap device. Then, a prolapse was simulated on the cap, and the student had to take the relevant measurements and record them in the POPQ grid. The main training effect to understand the POPQ system seems to be the possibility for each trainee to simulate a three-dimensional prolapse with this flexible vagina model.

Disease Progression↗

The plateau iris component of primary angle closure glaucoma: developmental or acquired.

Primary angle closure glaucoma has been called the most common form of glaucoma in the world, and the leading cause of bilateral blindness. Pupillary block is felt to be the main mechanism of outflow obstruction in this condition. Recent advances in morphologic assessment of angle closure, specifically by means of ultrasound biomicroscopy, have revealed that plateau iris in eyes with angle closure glaucoma is more common than had previously been thought. The most characteristic finding in this disease is thicker and more anteriorly positioned lens. This induces the pupillary block that relives by laser iridotomy. Residual angle closure after laser iridotomy is due to the plateau iris. Peripheral iridoplasty, the standard treatment of plateau iris, tights the peripheral iris and opens the angle but has no effect on the ciliary processes configuration. The ciliary processes are positioned posteriorly after lens extraction but dose not disappears completely. Considering these facts we hypothesized that the plateau iris in primary angle closure glaucoma is a developmental entity that reaches to a critical stage with aging owing to the thickening and forward movement of the lens. Cataract surgery deeps the anterior chamber, widens the irido-corneal angle and reposits the ciliary processes posteriorly, so it can prevents synechia formation and progressive lens-induced angle narrowing and plateau iris progression, the acquired component, with aging.

Disease Progression↗