Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging.

Abstract

Three dimensional terahertz pulsed imaging (TPI) was evaluated as a novel tool for the nondestructive characterization of different solid oral dosage forms. The time-domain reflection signal of coherent pulsed light in the far infrared was used to investigate film-coated tablets, sugar-coated tablets, multilayered controlled release tablets, and soft gelatin capsules. It is possible to determine the spatial and statistical distribution of coating thickness in single and multiple coated products using 3D TPI. The measurements are nondestructive even for layers buried underneath other coating structures. The internal structure of coating materials can be analyzed. As the terahertz signal penetrates up to 3 mm into the dosage form interfaces between layers in multilayered tablets can be investigated. In soft gelatin capsules it is possible to measure the thickness of the gelatin layer and to characterize the seal between the gelatin layers for quality control. TPI is a unique approach for the nondestructive characterization and quality control of solid dosage forms. The measurements are fast and fully automated with the potential for much wider application of the technique in the process analytical technology scheme.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Axel Zeitler, Yaochun Shen, Colin Baker, Philip F Taday, Michael Pepper, Thomas Rades. 2007. Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging.. https://doi.org/10.1002/jps.20789

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Successful transfection of hepatoma cells after encapsulation of plasmid DNA into negatively charged liposomes.

The application of conventional cationic liposomes/DNA complexes in gene transfer was hampered due to their large size, instability, and limited transfection site in vivo. In this report, we described a dialysis-based method and produced small, stable, and negatively charged DNA-containing liposomes composed of low content of cationic lipid and high content of fusogenic lipid. The liposomes were relatively spherical with a condensed core inside, and exhibited small size with narrow particle size distribution. The encapsulation efficiency of the liposomes was 42.53 +/- 2.29%. They were stable and showed enough protective ability to plasmid DNA from degradation after incubation with different amounts of DNase. Twenty-fold higher transfection efficiency for the liposomes was achieved when compared with that of naked plasmid DNA and no toxicities to hepatocellular carcinoma cells were observed. Our results indicate that the negatively charged DNA-containing liposomes can facilitate gene transfer in cultured cells, and may alleviate the drawbacks of the conventional cationic liposomes/DNA complexes for gene delivery in vivo.

Capsules↗

Hard gelatin and hypromellose (HPMC) capsules: estimation of rupture time by real-time dissolution spectroscopy.

The objective of this study was to measure rupture time of gelatin and hypromellose (hydroxypropyl methylcellulose or HPMC) capsules using a novel approach based on real-time dissolution spectroscopy. Rupture time was measured in standard dissolution apparatus at a constant temperature using a dip-type fiber-optic probe. Labrasol released from the capsules was treated as the marker of the rupture process. Light scatter generated by the emulsified labrasol was detected by an ultrafast monochromator at scan rates approximating 24,000 nm/min. This technique was validated by measuring the dissolution time of gelatin capsules. Rupture times of hypromellose capsules were studied as a function of capsule size, capsule grade, and dissolution medium. Statistical correlations were analyzed by ANOVA. Rupture time of hypromellose capsules was dependent on both the medium and the grade of the capsule, and was independent of capsule size. The composition of the dissolution medium contributes to the rupture time of the capsules and should be considered when fast release and quick biological response is desired. Release delay, however, may not manifest itself in vivo and the time to maximum plasma concentration may not be significant.

Capsules↗