PubMed · 17081047
Comparison of hydroxylated print additives on antibody microarray performance.
Abstract
Various hydroxylated additives were added to antibody print buffers at different concentrations to stabilize printed antibodies during normal array spot desiccation on commercial polymer-coated microarray slides. Polyvinyl alcohol addition to print buffers produced the most regular spot morphologies, homogeneous intra-spot antibody distribution, uniform fluorescence intensity, and improved analyte capture activity, maintained up to 1 month at 4 degrees C for capturing model analytes, anti-human IL-1beta, IL-4, and TNFalpha, on these microarraying slides.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Peng Wu, David W Grainger. 2006. Comparison of hydroxylated print additives on antibody microarray performance.. https://doi.org/10.1021/pr060217d