An injury to a finger or toe can result in a collection of blood under the nail plate that if unrelieved can cause extreme discomfort due to pressure. In this case, a 47-year-old man developed a subungual hematoma of the right thumb due to a crush injury. Controlled nail trephination was performed using a uniquely designed drill that penetrated the nail plate without breaching the nail bed. The subungual hematoma was successfully drained, and there was a substantial relief in pain over the subsequent 8 hours. This technique appears to be a quick and convenient method of evacuating subungual hematomas with minimal discomfort and minimal risk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sharon A Salter, David H Ciocon, Thiruvallur R Gowrishankar, Alexa B Kimball. 2006. Controlled nail trephination for subungual hematoma.. https://doi.org/10.1016/j.ajem.2006.03.029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗