Computer controlled stereotaxic radiotherapy system.

Abstract

A computer-controlled stereotaxic radiotherapy system based on a low-frequency magnetic field technology integrated with a single fixation point stereotaxic guide has been designed and instituted. The magnetic field, generated in space by a special field source located in the accelerator gantry, is digitized in real time by a field sensor that is six degree-of-freedom measurement device. As this sensor is an integral part of the patient stereotaxic halo, the patient position (x, y, z) and orientation (azimuth, elevation, roll) within the accelerator frame of reference are always known. Six parameters--three coordinates and three Euler space angles--are continuously transmitted to a computer where they are analyzed and compared with the stereotaxic parameters of the target point. Hence, the system facilitates rapid and accurate patient set-up for stereotaxic treatment as well as monitoring of patient during the subsequent irradiation session. The stereotaxic system has been developed to promote the integration of diagnostic and therapeutic procedures, with the specific aim of integrating CT and/or MR aided tumor localization and long term (4- to 7-week) fractionated radiotherapy of small intracranial and ocular lesions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P V Houdek, J G Schwade, C F Serago, H J Landy, V Pisciotta, X D Wu, A M Markoe, A A Lewin, A A Abitbol, J L Bujnowski. 1992. Computer controlled stereotaxic radiotherapy system.. https://doi.org/10.1016/0360-3016(92)90997-v

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Surface enhanced Raman optical activity of molecules on orientationally averaged substrates: theory of electromagnetic effects.

We present a model for electromagnetic enhancements in surface enhanced Raman optical activity (SEROA) spectroscopy. The model extends previous treatments of SEROA to substrates, such as metal nanoparticles in solution, that are orientationally averaged with respect to the laboratory frame. Our theoretical treatment combines analytical expressions for unenhanced Raman optical activity with molecular polarizability tensors that are dressed by the substrate's electromagnetic enhancements. We evaluate enhancements from model substrates to determine preliminary scaling laws and selection rules for SEROA. We find that dipolar substrates enhance Raman optical activity (ROA) scattering less than Raman scattering. Evanescent gradient contributions to orientationally averaged ROA scale to first or higher orders in the gradient of the incident plane-wave field. These evanescent gradient contributions may be large for substrates with quadrupolar responses to the plane-wave field gradient. Some substrates may also show a ROA contribution that depends only on the molecular electric dipole-electric dipole polarizability. These conclusions are illustrated via numerical calculations of surface enhanced Raman and ROA spectra from (R)-(-)-bromochlorofluoromethane on various model substrates.

Electromagnetic Phenomena↗

A simple and accurate method for quantification of magnetosomes in magnetotactic bacteria by common spectrophotometer.

A simple apparatus for measuring the magnetism of magnetotactic bacteria was developed with a common laboratory spectrophotometer, which was based on measuring the change in light scattering resulting from cell alignment in a magnetic field. A multiple coils were built around the cuvette holder of the spectrophotometer to compensate geomagnetic field and to generate two mutually perpendicular magnetic fields. In addition, we defined a novel magnetism parameter, R(mag), by modifying the definition of C(mag) to a normalized parameter with the culture absorbance obtained without application of magnetic field. The number of magnetosomes in each cell was determined by transmission electron microscopy to assess the relationship between the two magnetism parameters and the distribution of magnetosomes in the cells. We found that both R(mag) and C(mag) were linearly correlated rather with the percentage of magnetosome-containing bacteria than with the average magnetosome numbers, and R(mag) exhibited a better linearity than C(mag) with respect to the percentage of magnetosome-containing bacteria.

Electromagnetic Phenomena↗

Symmetry breaking in individual plasmonic nanoparticles.

The plasmon resonances of a concentric metallic nanoshell arise from the hybridization of primitive plasmon modes of the same angular momentum on its inner and outer surfaces. For a nanoshell with an offset core, the reduction in symmetry relaxes these selection rules, allowing for an admixture of dipolar components in all plasmon modes of the particle. This metallodielectric nanostructure with reduced symmetry exhibits a core offset-dependent multipeaked spectrum, seen in single-particle spectroscopic measurements, and exhibits significantly larger local-field enhancements on its external surface than the equivalent concentric spherical nanostructure.

Electromagnetic Phenomena↗