PubMed Health⌕ Search

PubMed · 1744477

Multivariable optimization of mechanical ventilation. A linear programming approach.

Abstract

The proposed method aims at improved ventilatory care with reduced morbidity. It combines two important aspects of mechanical ventilation: gas exchange and lung mechanics. A single criterion was selected as optimization index of lung trauma: peak respiratory power (PRP) defined as the maximum product of pressure times flow during inspiration. Arterial blood gases reflect gas exchange and constitute the constraints of the problem. The constraints as well as the optimization index are expressed as linear functions of the input variables (frequency of breathing, tidal volume, and positive end expiratory pressure). A linear programming approach can therefore be used to determine the values of input variables that minimize PRP and at the same time keep arterial blood gases within the prescribed limits. The coefficients of the constraints and the optimization index equation are found by manipulating input variables in order to obtain four different values of PaO2, PaCO2 and PRP (there are four coefficients in each equation). The coefficients can then be calculated and the optimization procedure run. In a pilot study 5 patients suffering from diseases of varying pulmonary pathology were investigated with this method. In 4 out of 5 the ventilator treatment improved in terms of blood gas values (mean increase in PaO2 was 4.7%) and reduction of mechanical load on the lungs (mean PRP reduction was 20%). Lower PRP is accompanied by lower mean power and pressure values, which results in increased cardiac output. Presently, the main problem is the time it takes to determine the patient coefficients (approx one hour), a procedure that needs to be simplified.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Rudowski, A Bokliden, A Carstensen, H Gill, U Ludwigs, G Matell. 1991. Multivariable optimization of mechanical ventilation. A linear programming approach.. https://doi.org/10.1007/bf02915544

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗