PubMed · 1752790
Objective auditory threshold estimation using sine-wave derived responses.
Abstract
A derived response method of acquiring frequency specific auditory evoked potentials that utilizes a pure tone in combination with a toneburst is applied to the measurement of hearing sensitivity in guinea pigs, chinchillas and pocket gophers. Two experiments which demonstrate that thresholds acquired via tone-derived responses are 10 to 15 dB more sensitive than thresholds to solitary tonebursts are described. The derived potentials approximate behaviorally acquired thresholds at frequencies of 0.5 kHz and above. This technique may provide a more rapid means of assessing hearing sensitivity in laboratory animals than by behavioral means.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
L J Hood, C I Berlin, R S Heffner, C R Morehouse, E G Smith, E K Barlow. 1991. Objective auditory threshold estimation using sine-wave derived responses.. https://doi.org/10.1016/0378-5955(91)90097-s