Methods of determining bone mass.

Abstract

Bone disease is one of the most important clinical manifestations of primary hyperparathyroidism. Recent studies have shown that the loss of bone in "modern" hyperparathyroidism is not homogeneous throughout the skeleton. Whereas measurements of the spine and the trabecular portion of iliac crest are normal or even slightly increased, the wrist and the cortical bone of the iliac crest are significantly lower than expected. Thus, knowledge of the percentage of trabecular bone at each measurement site is important. These include distal radius, 80%; midradius, 5%; vertebrae, 19-25%; vertebral body, 33-42%; and femoral neck, 43%. Knowledge of the precision and its relationship to ranges and rates of change of bone mass are essential. For an individual, the bone mass should change by 2.8 times the precision before one can determine with 90% confidence that the change was real, not due to measurement error. Noninvasive methods of measuring bone mass that are commercially available include single- and dual-photon absorptiometry, quantitative computed tomography, and dual-energy x-ray absorptiometry. The precision of these techniques varies, with the best values reported using dual-energy x-ray absorptiometry. Research should be done to describe more completely the patterns of bone loss in this disease, including longitudinal studies on rates of loss at different skeletal sites. Studies that relate the bone mass at a particular site to fractures must be done in populations with hyperparathyroidism to see if the risk of fracture is similar to the risk in normal or osteoporotic individuals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S M Ott. 1991. Methods of determining bone mass.. https://doi.org/10.1002/jbmr.5650061416

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗