PubMed HealthSearch

PubMed · 1775260

Biocompatibility and membrane development.

Abstract

Development of new biocompatible membranes for clinical application needs the expertise of various specialists, chemists, chemical engineers, and clinicians. As the biocompatibility of a membrane cannot be considered in terms of a single biochemical pathway, due to the interrelation between the complement, coagulation, and inflammatory systems, it is difficult to achieve optimal results with one single polymer. A compromise between different approaches has therefore to be found. Membrane development also needs sophisticated test systems, which simulate the clinical situation as closely as possible. Adequate results are achieved with the 'ex vivo' model, which represents open-loop haemodialysis. The ex vivo model gives good results which are close to those from clinical experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Baurmeister, J Vienken, A Grassmann. 1991. Biocompatibility and membrane development.. https://pubmed.ncbi.nlm.nih.gov/1775260/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Value of routine follow-up after infrainguinal arterial reconstruction].

Longterm patency of infrainguinal bypass procedures may be established on the basis of clinical evaluation and ankle pressure measurements. With the aim of assessing whether these parameters could predict grafts at risk for occlusion, we identified 24 patients in whom the bypass had occluded between 3 and 12 months postoperatively, but following at least one follow-up. These patients were compared with a control group consisting of further 24 patients operated on during the same period, but in whom the bypass was patent. Prior to graft occlusion only nine (39%) patients had complained of claudication, and a significant drop in ankle pressure was demonstrated in seven (29%) patients. These figures were significantly higher than the one (4%) patient in the control group who complained of claudication and the other (4%) patient who developed a drop in ankle pressure (p < 0.02 and 0.05, respectively). Graft surveillance based on patients' history and ankle pressure measurements are insufficient parameters for identification of grafts at risk for occlusion. However, the occurrence of claudication and/or a significant drop in ankle pressures are associated with a high incidence of graft thrombosis.

Biocompatible Materials

[Implantation of a Stecker metal prosthesis in malignant stenosis of the gastric stump].

A 55 year old patient 3 years after gastric resection (Billroth II) has got gastric outlet stenosis. Half year ago was established a tumour recidive, that the time of reoperation was inoperable. Under endoscopic and radiological control we have introduced and placed a 19 mm diameter, 4 cm long balloon expandable tantalum stent (Strecker stent). The gastric passage has normalised and after 6 month the patient is symptom free.

Biocompatible Materials