PubMed Health⌕ Search

PubMed · 1786695

Finnish PACS project.

Abstract

A Finnish PACS project has been set up with the participation and financing of 13 university and central hospitals, the Medical Board of Finland, the Hospital League of Finland, the Post and Teleoffice of Finland and the Helsinki Telephone Company with the Medical Engineering Laboratory of the Technical Research Centre of Finland as the principal investigator. The project started in December 1988 and ended in December 1990. The project focused on the functional needs for PACS. The image production, archive sizes, network capacity and workstation requirements have been studied in a big university hospital. The results show that without compression the image archive size needs to be at least 10 TB. The network capacity requirement depends very much on the interactivity requirements. In normal situations less than 1 Mbit/s is needed, if the network is configured in an efficient way. In some cases, however, the speed requirement can be of the order of 100 Mbit/s. A proposal for a hospital-wide PACS network was made. Simple calculation rules to estimate the needed capacities were also developed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Viitanen, A Kiuru, K Heiska, A Kärkkäinen, M Kormano. Finnish PACS project.. https://doi.org/10.1016/0169-2607(91)90054-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗