Multicomponent analysis: a case report.

Abstract

Three cases are described. Case 1: kinetic studies often need high time resolution measurements in order to follow the pattern of reactions taking place during the experiment. This is often laborious to achieve with the collection of fractions for chromatographic separation. Some tool for separation is, however, necessary in order to decompose the concentrations of reactants, products and intermediate species. The spectra of the intermediates may not be known at the time when the kinetic studies are needed. With unknown spectra there are still possibilities to use spectroscopy and multivariate techniques to obtain qualitative information. Case 2: it is possible to use Partial Least Squares (PLS) in order to describe the chromatographic profiles for the species even if the separation is insufficient for traditional peak measurement methods. This requires that mixtures are available with known concentrations of the species to be determined. Case 3: with modern diode array liquid chromatography detectors there is the possibility to capture the chromatogram and the spectra at the same time. The ability to reproduce the chromatographic profile between samples makes it possible to use the Generalized Rank Annihilation Method (GRAM) possible. Whereas PLS only treats one spectrum at a time, this method treats the full two-dimensional chromatogram as an entity. The GRAM calibration is claimed to be insensitive to interfering species which are not present in the calibration. Limitations are that GRAM requires a linear detector response and very good repeatability of the retention time. The use of GRAM for calibration with real samples is demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Josefson, L Tekenbergs-Hjelte. 1991. Multicomponent analysis: a case report.. https://doi.org/10.1016/0731-7085(91)80190-k

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of eperisone in human plasma by gas chromatography-mass spectrometry.

A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.

Calibration

Video analysis of DNA sequence homologies.

A method for the rapid quantitative analysis of dot blot assays is presented. A video camera, an NTSC compatible frame grabber board, and an AT personal computer are used to read photographic exposures of the assay plate. Image processing and image analysis techniques are used to calculate the orientation of the dot raster and then to compensate for the effect of variations in field illumination on measurements of local contrast. Local contrast (between dots and background) is an exponential function of the amount of hybridization between blotted DNA and complimentary oligonucleotide probes. The amount of hybridization between blotted DNA and oligonucleotide probes of known sequence is the criteria used to establish HLA-DR tissue types. Although the assay described here utilizes a chemiluminescent reaction, this algorithm may be used to read any assay that produces a rectangular raster of dots.

Calibration

Analysis of terbutaline in human plasma by high-performance liquid chromatography with electrochemical detection using a micro-electrochemical flow cell.

A high-performance liquid chromatographic method is described for the determination of terbutaline in human plasma in the range 1-35 ng/ml. Detection was achieved using a carbon fibre micro-electrochemical detector and a column-switching system. The microelectrode cell has advantages over conventional glassy carbon electrode-based detection systems in that it is easy to prepare, flexible in its operation and suffers less trouble from problems such as air bubbles and leaks. Furthermore, it has a better detection limit for terbutaline (0.8 ng/ml) to that obtained using a conventional glassy carbon electrode flow detector (2 ng/ml). Sample clean-up was by on-line solid-phase extraction with column switching, providing a method which was sensitive and reproducible, where the mean overall coefficient of variation was 5.60% and drug recovery in excess of 86% at the concentration levels studied.

Calibration