PubMed Health⌕ Search

PubMed · 1808009

Risk assessment from bitewing radiography.

Abstract

The effective dose equivalent and the effective dose from bitewing radiography have been estimated for three different X-ray sets under 10 different exposure conditions using the ICRP 26 (1977) and the ICRP 60 (1990) recommendations. The results of dose measurements in the head and neck with an Alderson Rando phantom and thermoluminescence dosimeters (TLD-100 ribbons) were used (Velders XL et al. Dentomaxillofac Radiol 1991; 20: 161-5). The effective dose equivalent (ICRP 26) was calculated using the salivary glands and brain as remainder organs. The highest effective dose equivalent was 11 microSv for the Philips Oralix 50 unit with a round, pointed cone; the lowest was 2 microSv for the X-ray sets with a rectangular open-ended tube. The highest effective dose using the ICRP 60 weighting factors was 4 microSv for the Oralix 50, the lowest 1 microSv for the X-ray sets with a rectangular open-ended tube. The probability of stochastic effects was calculated as at the most 0.18 x 10(-6) using a nominal probability coefficient of 165 x 10(-4) Sv-1 (ICRP 26); when using the ICRP 60 recommendations (where the nominal probability coefficient for stochastic effects including non-fatal cancer is 730 x 10(-4) Sv-1) the maximum probability was 0.25-0.31 x 10(-6). The maximum probability of fatal cancer induction was calculated as 0.18 x 10(-4) for both fatal probability coefficients, 125 x 10(-4) Sv-1 in ICRP 26 and 500 x 10(-4) Sv-1 in ICRP 60. The calculated probability of the total stochastic effects is nearly twice as high when using the new recommendations, whilst the estimated probability of fatal cancer induction is of the same order of magnitude with both.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

X L Velders, J van Aken, P F van der Stelt. 1991. Risk assessment from bitewing radiography.. https://doi.org/10.1259/dmfr.20.4.1808009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗