Mammographically indeterminate microcalcifications--can we do any better?

Abstract

In the first round of the mammographic screening program of the South Australian Breast X-ray Service, 80 (0.73%) of the first 10,848 women screened over 18 months were referred after primary and second-stage assessment for definitive histology because of microcalcifications. Obvious mass lesions associated with calcification were excluded from this study, as were women whose calcification was regarded as sufficiently benign to warrant routine rescreening in two years. After classic patterns of malignant microcalcification were excluded, a large group (75%) remained, whose calcifications fell into the indeterminate grades of radiological suspicion. Of these, only 15% proved to have cancer, and in one third of these the cancer was mammographically occult. A high rate of discordant readings was noted in lesions which ultimately proved benign. Neither family history, distribution of calcification nor the presence of a faint soft tissue density proved to be unfailingly reliable predictors of benign or malignant histology in this group. Vigorous pursuit of histopathological correlation and performance statistics are urged to monitor and minimise the proportion of women who remain in this indeterminate group and to follow their natural history. Current mammographic techniques are still inadequate for the provision of definitive information on microcalcification in all cases, but a sustained commitment will reduce the number proceeding to histology for benign disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L E Albertyn. 1991. Mammographically indeterminate microcalcifications--can we do any better?. https://doi.org/10.1111/j.1440-1673.1991.tb03046.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of 4 MV photon surface dose among Varian, Siemens, and Elekta linear accelerators for tangential breast treatment: a phantom study.

PURPOSE: We have compared the differences in a 4-MV photon surface dose among Varian, Siemens, and Elekta linear accelerators (linacs) with wedges for tangential breast treatment. MATERIALS AND METHODS: The wedge factor and the surface dose were measured using a solid water phantom and an ion chamber for each linear accelerator with various field sizes and wedge angles. A tangential treatment plan was applied to an elliptical hollow cylinder water phantom with a radiochromic film placed thereon. A dose was delivered to a simulated target in the phantom, and the resulting dose distribution was analyzed using a film scanner. RESULTS: Varian's wedges resulted in the highest wedge factors, ranging from 0.37 to 0.75 depending on the wedge angles. Varian's wedges led to the highest normalized skin doses, ranging between 0.40 and 0.73 depending on the wedge angles and field sizes. In the cylinder phantom test with two tangential beams, the Varian linac provided a nearly 20% higher maximum dose than the Siemens and Elekta linacs. CONCLUSION: The Varian linac resulted in the highest surface doses, and the Elekta linac led to the lowest for nearly all the measurement conditions we employed, including open beams.

Breast Diseases↗

[Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?].

PURPOSE: To analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). MATERIAL AND METHODS: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, USA ) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. RESULTS: The mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6 %, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3 %, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). CONCLUSION: A statistically significant effect of the use of CAD could not been detected dependent on the radiological experience or the CAD experience. The effect of CAD on radiologists is still subtle despite the highly sensitive CAD performance due to the high number of false positive prompts and thus does not reach statistical significance. Sizes given by CAD prompts correlate significantly with the real sizes of malignant lesions.

Breast Diseases↗