PubMed HealthSearch

PubMed · 1816830

[The bite-jumping-appliance].

Abstract

By the development of the bite-jumping-appliance (BJA) the wearing comfort for the patient was significantly improved and also the handling through the doctor was multiple facilitated. 1. While treating with the BJA the forward advancement of the mandible can be done simultaneously with the harmonizing of the maxillary and mandibular dental arches. 2. The wearing comfort during the day time, as well as the speech with the BJA in the patients mouth is possible without any problems due to the fact, that the BJA consist of two separate appliances. 3. The functioning of the BJA can be improved while using extraoral forces. Also the wearing of the BJA without extraoral forces leads to a headgear effect onto the maxilla. 4. Also uncontrolled muscle activities during the night leads, if the muscle activity is great enough, to a total biting together. 5. To avoid the contact between protrusive sticks and inclined plane in the lower appliance, the patient will bring unconsciously the mandible, while speaking during day time, in a more anterior position. This training effect leads to an accelerated forward advancement of the mandible as well as to an accelerated harmonizing of the muscular chewing pattern in the anterior position. 6. A harmonized muscular chewing pattern in the sagittal plane as well as in the frontal plane can be achieved in nearly all patients after finishing the BJA-therapy. These results couldn't be achieved with other bimaxillary appliances [28].

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F G Sander, A Weinreich. 1991. [The bite-jumping-appliance].. https://pubmed.ncbi.nlm.nih.gov/1816830/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intermaxillary forces during activator treatment.

The mode of action of the activator appliance is still unclear. Apart from a possible mandibular growth enhancing effect, some investigators believe that orthopedic forces may be applied to the maxilla, contributing to Class II correction by inhibition of maxillary growth. In addition, orthodontic forces may arise that produce dentoalveolar changes. The purpose of this study was to measure the magnitude of anteroposterior intermaxillary forces during wear of the activator appliance. Ten consecutive patients with Class II dental and skeletal relationships were treated with a modified activator appliance. The appliance had maxillary and mandibular segments that could be detached from each other during the measuring session. A force transducer was placed at the anterior part of the maxillary segment, and the anteroposterior force exerted by the mandibular segment was measured. Measurements were taken in the upright and reclined position at every patient visit for a period of 6 months. Results indicated that intermaxillary forces were generally in the orthodontic range (median values of 100 gf at the upright position and 123 gf at the reclined position). A wide variation in force levels was noted, both between patients and for the same patient during the experimental period. No statistically significant change in force levels was observed during the 6 month period and no difference was noted between upright and reclined posture.

Activator Appliances

The influence of the spring activator on the mobility of the lower jaw in traumatically injured patients.

For functional rehabilitation and improvement of mandibular mobility, 14 patients with dislocated collum or collum fracture dislocations were treated with a spring activator after surgical-conservative treatment. With an interincisal distance of < 12 mm, therapy was started with a loop spring. The average age of the patients was 26.6 years. Eight patients showed additional traumatic injuries, 2 patients were seriously polytraumatically injured. The clinical investigations referring to the maximum mouth opening and maximal interincisal distance resulted in a good to very good functional rehabilitation in all cases. The average maximal interincisal distance of 31.7 mm at the beginning of the spring activator therapy could be increased to 47.3 mm. The largest increase of the maximal interincisal distance was observed after 4 weeks of therapy. The type of reaction, however, differed interindividually. Three patients showed a spontaneous improvement of the interincisal distance within the first 2 to 3 weeks of removal of intermaxillary fixation, whereas 7 patients showed no improvement or only slightly improved values until insertion of the spring activator. An enlargement of the interincisal distance could be achieved in almost every patient within a relatively short period of time despite a drastically reduced mouth opening. Consequently, because of its mode of action in the form of a neuromuscular influence, the spring activator is especially suitable for the functional rehabilitation of patients with fractures of the condylar process.

Activator Appliances

Incisor torque by means of a modified Teuscher activator. Three case reports.

It is generally accepted that in the treatment of Class II, 1 malocclusion classical activators may tip the upper incisors considerably. In comparison, in the cases described, an even better torque control was obtained. It has been our clinical experience that with the modified Teuscher activator it is possible to control upper incisor inclination and in some cases it is even possible to induce active palatal root torque. The appliance is relatively comfortable with good vertical retention even without headgear.

Activator Appliances