PubMed Health⌕ Search

PubMed · 1821387

Sick-building syndrome.

Abstract

The sick-building syndrome (SBS) is defined as the occurrence of an excessive number of subjective complaints by the occupants of a building. These complaints include headache, irritation of the eyes, nose, and throat, lethargy, inability to concentrate, objectionable odors, and less frequently, nausea, dizziness, chest tightness, etc. These complaints will always be reported by a fraction of the occupants of any building if a questionnaire is administered that asks the respondent to recall any subjective symptoms they remember having had in the last 2 weeks or or over some period of time. It is often considered that SBS symptom reports have a minimum prevalence of about 15 to 20% for a 2-week recall period. SBS symptoms reported by 30% or more of occupants are indicative of conditions in the building environment that warrant attention. It is not often that a clear, single cause is responsible for the excess symptom reports. The following factors, often in combinations, are seen to contribute to SBS: outdoor air supply that is inadequate, ventilation distribution or effectiveness that is inadequate, the presence of temporary or long-term sources of contaminants such as tobacco smoke, adhesives, composite materials such as chipboard, and the growth of microorganisms in the HVAC equipment or in carpets or other furnishings. Depending on which causes contribute, the condition may be intermittent or even temporary. Psychosocial factors such as labor-management relations and satisfaction or dissatisfaction with other factors in the work environment can have a profound influence on the level of response of the occupants to their environment. Although hard data are difficult to collect, it is likely that productivity in the office environment is sensitive to conditions causing SBS.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Stolwijk. 1991. Sick-building syndrome.. https://doi.org/10.1289/ehp.919599

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pilot study of indoor radon in Greek workplaces.

Radon and gamma dose rate measurements have been performed in 561 workplaces in 19 prefectures of Greece. The distribution of radon concentration can be well described by a log-normal distribution. Most of the radon concentrations are between 50 and 200 Bq m(-3) with an arithmetic mean of 123 Bq m(-3). The maximum measured value of radon gas concentration is 695 Bq m(-3). About 10% of the workplaces exceed 200 Bq m(-3). Only a small fraction ( approximately 1%) of workplaces exceed the European Commission action level (400 Bq m(-3)). Despite the relative small fraction of workplaces which exceed the value of 400 Bq m(-3), it is clear from the results of the present work that for certain prefectures, further and more extensive research is needed.

Air Pollution, Indoor↗

Health effects of arsenic, fluorine, and selenium from indoor burning of Chinese coal.

China's economy has developed rapidly in the last two decades, leading to an increase in energy consumption and consequently emissions from energy generation. Coal is a primary energy source in China because of its abundance and will continue to be used in the future. The dominance of coal in energy production is expected to result in increasing levels of exposure to environmental pollution in China. Toxic trace elements emitted during coal combustion are the main sources of indoor air pollution. They are released into the atmosphere mainly in the forms of fine ash and vapors and have the potential to adversely affect human health. Those trace elements, which volatilize during combustion, are hazardous air pollutants (HAPs) and are particularly rich in Chinese coals. Among the HAPs, arsenic (As), fluorine (F), and selenium (Se) have already been identified as pollutants that can induce severe health problems. In this review, the geochemical characteristics of As, F, and Se, including their concentration, distribution, and mode of occurrences in Chinese coal, are documented and discussed. Our investigations have confirmed the current As- and F-induced epidemics in Guizhou (Southwest China) and Se epidemic in Hubei (Northeast China). In this study, diagnostic symptoms of arseniasis, fluorosis, and selenosis are also illustrated.