Peripheral vision lipreading aid.

Abstract

Lipreading provides a limited amount of information about speech signals to profoundly deaf people. Visual displays using peripheral vision as an alternative sensory modality can provide supplementary speech information. The utility of a cosmetically acceptable peripheral vision display was explored. A pair of eyeglasses with a commercially available two-dimensional red LED array (5 x 7), and its associated electronics was developed. The display is visible only to the wearer, and is located in the temporal field and the horizontal meridian of the right eye. Selected speech features were encoded as visual patterns for presentation to the lipreader. These features of the speech signal (the fundamental frequency of the speech, high-frequency energy, and low-passed speech signal or total energy envelope) were presented with the objective of providing information about voicing and plosion/frication. Experiments demonstrate the capability of the peripheral display in conveying speech information. Presenting vowel-consonant-vowel syllables, the performance was in excess of 76% with aided lipreading as compared to 41% by lipreading only.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Ebrahimi, H Kunov. 1991. Peripheral vision lipreading aid.. https://doi.org/10.1109/10.88440

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A head movement image (HMI)-controlled computer mouse for people with disabilities.

PURPOSE: This study proposes image processing and microprocessor technology for use in developing a head movement image (HMI)-controlled computer mouse system for the spinal cord injured (SCI). METHOD: The system controls the movement and direction of the mouse cursor by capturing head movement images using a marker installed on the user's headset. In the clinical trial, this new mouse system was compared with an infrared-controlled mouse system on various tasks with nine subjects with SCI. RESULTS: The results were favourable to the new mouse system. The differences between the new mouse system and the infrared-controlled mouse were reaching statistical significance in each of the test situations (p<0.05). CONCLUSIONS: The HMI-controlled computer mouse improves the input speed. People with disabilities need only wear the headset and move their heads to freely control the movement of the mouse cursor.

Communication Devices for People with Disabilities↗

A brain-computer interface (BCI) for the locked-in: comparison of different EEG classifications for the thought translation device.

OBJECTIVE: The Thought Translation Device (TTD) for brain-computer interaction was developed to enable totally paralyzed patients to communicate. Patients learn to regulate slow cortical potentials (SCPs) voluntarily with feedback training to select letters. This study reports the comparison of different methods of electroencephalographic (EEG) analysis to improve spelling accuracy with the TTD on a data set of 6,650 trials of a severely paralyzed patient. METHODS: Selections of letters occurred by exceeding a certain SCP amplitude threshold. To enhance the patient's control of an additional event-related cortical potential, a filter with two filter characteristics ('mixed filter') was developed and applied on-line. To improve performance off-line the criterion for threshold-related decisions was varied. Different types of discriminant analysis were applied to the EEG data set as well as on wavelet transformed EEG data. RESULTS: The mixed filter condition increased the patients' performance on-line compared to the SCP filter alone. A threshold, based on the ratio between required selections and rejections, resulted in a further improvement off-line. Discriminant analysis of both time-series SCP data and wavelet transformed data increased the patient's correct response rate off-line. CONCLUSIONS: It is possible to communicate with event-related potentials using the mixed filter feedback method. As wavelet transformed data cannot be fed back on-line before the end of a trial, they are applicable only if immediate feedback is not necessary for a brain-computer interface (BCI). For future BCIs, wavelet transformed data should serve for BCIs without immediate feedback. A stepwise wavelet transformation would even allow immediate feedback.

Communication Devices for People with Disabilities↗