PubMed Health⌕ Search

PubMed · 1873132

The total artificial heart.

Abstract

In the early 1800s, an awareness of potential ventricular failure stimulated interest in artificial heart replacement. In 1937 the first total artificial heart (TAH) was implanted into the chest of a dog by Russian physicians. The primary driving force for mechanical cardiac assistance developed from the necessity for circulatory assistance in order to perform corrective cardiac surgery. In 1953 the first successful closure of an atrial septal defect using extracorporeal circulation was performed. During the following decade the concept of using mechanical devices to assist the failing heart was aggressively pursued. This culminated in the first implant of a TAH in a human in 1969 as a bridge to transplant. Clinical implant of the TAH as a permanent device was performed in 1982 by researchers at the University of Utah. This patient lived for 112 days. Three successive permanent implants were performed in Louisville, Kentucky, with one patient surviving for 620 days. All of these permanent TAH patients suffered from device-related complications including bleeding, infection, and thromboembolic events. It became apparent that the present configuration of the TAH with its external drive lines and large air console was not ideal for long-term support. In 1985 the first implant of the Symbion J-7-100 TAH (Jarvik-7) as a bridge to transplant was performed. This patient was supported by the device for 9 days and was successfully transplanted and discharged home. Since 1985 more than 170 patients have been bridged using the Symbion J-7 TAH with more than 70% of these patients being successfully transplanted. The incidence of thromboembolic events has dramatically reduced with better understanding of anticoagulation requirements. Infection continues to be the greatest potential complication with these patients. In spite of this, the pneumatic TAH has proved to be an adequate bridge to transplant device.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L E Barker. 1991. The total artificial heart.. https://doi.org/10.4037/15597768-1991-3022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗