Partially biodegradable polyacrylic-polyester composites for internal bone fracture fixation.
Abstract
New partially resorbable composite formulations based on components used in surgery were synthesized in rod form (length 15-20 mm, diameter 4 mm). The biostable components were poly(methyl methacrylate) in hydrophobic implants and poly(2-hydroxy ethyl methacrylate) in hydrophilic ones. The biodegradable components were commercially available suture yarn made from poly (alpha-hydroxy esters): polyglycolide, a polyester derived from glycolic acid; and a copolyester of glycolic and lactic acids, polyglactin 910. Biodegradation in phosphate-buffered solution at pH 7.0 and 37 +/- 0.5 degrees C was analysed gravimetrically. There was no measurable loss of mass after treatment for 20-25 d. Composite microstructure was examined by phase-contrast, cross-polarized light microscopy.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J San Román, P Guillén García. 1991. Partially biodegradable polyacrylic-polyester composites for internal bone fracture fixation.. https://doi.org/10.1016/0142-9612(91)90206-p. https://pubmed.health/record/pubmed%3A1878459/partially-biodegradable-polyacrylic-polyester-composites-for-internal-bone-fracture-fixation