Noise correlation.

Abstract

Calculations and experiments that provide support for our previously stated theorem are presented: If two coils simultaneously receiving magnetic resonance signals from the same anatomic region exhibit zero mutual inductance, there can be no correlation of the noise. It is shown that correlation does not exist even in the presence of mutual inductance unless the two signal paths have amplifiers prior to signal combination. It is further found that in the presence of mutual inductance with ideal amplifiers (0 dB noise figure) in the two signal paths, there is no correlation of noise. In order to satisfy the condition of zero mutual inductance, it may be necessary to employ a decoupling circuit external to the body. A novel coil assembly, which was used in the experiments, places a single-turn surface coil in the median plane between the two loops of a counter rotating current coil. The signal-to-noise ratio can be improved by combining signals. This is in analogy to quadrature receiving coils, where the mutual inductance is zero because vector reception fields are perpendicular. In the present geometry, vector reception fields are collinear, but are parallel and antiparallel on the two sides of the coil assembly, resulting in zero mutual inductance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Jesmanowicz, J S Hyde, W Froncisz, J B Kneeland. 1991. Noise correlation.. https://doi.org/10.1002/mrm.1910200105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design and evaluation of shielded gradient coils.

Techniques are described for the design of shielded gradient coils for superconducting MRI systems. These design methods are suited for constructing the most efficient gradient coil that meets a specified homogeneity requirement. Tradeoffs in coil design of efficiency with coil size and gap size are discussed. Residual eddy currents from coils constructed with a finite number of wires are calculated and give guidelines for the construction of efficient, whole-body gradient coils.

Amplifiers, Electronic

A piezoelectric respiratory monitor for in vivo NMR.

This report describes a simple electronic device employing a piezoelectric element which serves as a sensitive detector of motion. The device is useful as a monitor of respiratory motion for nuclear magnetic resonance animal experiments in vivo. It can also provide a trigger pulse for respiratory gating experiments.

Amplifiers, Electronic

Correction for liquid junction potentials in patch clamp experiments.

This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.

Amplifiers, Electronic