PubMed Health⌕ Search

PubMed · 1955776

Local complement activation in inflammatory bowel disease.

Abstract

To trace sites for local complement activation in inflammatory bowel disease, an indirect two-colour immunofluorescence method was applied on prewashed and directly ethanol-fixed mucosal specimens from patients with ulcerative colitis, Crohn's colitis, or terminal ileitis. Monoclonal antibodies to the IgG subclasses and to neoepitopes of activated complement C3b and the terminal complement complex (TCC) were used in combination with rabbit antiserum to immunoglobulins and various complement components. Deposits of activated C3b were found on the luminal face of the surface epithelium in the most affected ulcerative colitis specimens from 91% of 23 studied patients, together with cytolytic TCC in 81%. Furthermore, there was a selective deposition of the immunoglobulin G subclass 1 (IgG1) within the epithelial immune complexes in 63% of 11 studied patients. These results suggested that IgG1 autoantibodies to brush-border antigen(s) induce a complement-mediated attack on the epithelium in ulcerative colitis. The epithelial complement deposition seen in Crohn's disease tended to be more granular and was observed in 5 of 10 patients with colitis and in 4 of 10 with ileitis. No co-localization of IgG was observed, suggesting that complement activation had been induced by the alternative pathway. Type III immune reaction may, in addition, take place in both diseases since there was evidence of continuous vascular complement activation in submucosal blood vessels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T S Halstensen, P Brandtzaeg. 1991. Local complement activation in inflammatory bowel disease.. https://doi.org/10.1007/bf02919746

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Layer-by-layer assembly of biomacromolecules on poly(ethylene terephthalate) films and fiber fabrics to promote endothelial cell growth.

Poly(ethylene terephthalate) (PET) film and PET vascular graft were modified by layer-by-layer (LBL) assembly of collagen and chondroitin sulfate (CS) to mimic the natural composition and structure of extracellular matrix. PET materials were first hydrolyzed to endow the surfaces with negative charge. Alternative assembly of positively charged collagen and negatively charged CS was then conducted in an LBL manner to produce biological multilayers. X-ray photoelectron spectroscopy confirmed the occurrence of hydrolysis and existence of collagen and CS. The stepwise layer growth on the PET film was monitored by UV-vis spectroscopy. The multilayers had sufficient stability to pass through the cell culture period (8 days). In vitro endothelial cell culture revealed that the incorporated biomacromolecules could significantly improve the cell attachment, proliferation, and viability. Cells showed more spreading morphology with preserved phenotype, as illustrated by scanning electron microscopy and factor VIII-related antigen immunocytochemistry, respectively.

Blood Vessels↗

NPY receptors in human cancer: a review of current knowledge.

Many peptide hormone receptors are over-expressed in human cancer, permitting an in vivo targeting of tumors for diagnostic and therapeutic purposes. NPY receptors are novel and promising candidates in this field. Using in vitro receptor autoradiography, Y1 and Y2 receptors have been found to be expressed in breast carcinomas, adrenal gland and related tumors, renal cell carcinomas, and ovarian cancers in both tumor cells and tumor-associated blood vessels. Pathophysiologically, tumoral NPY receptors may be activated by endogenous NPY released from intratumoral nerve fibers or tumor cells themselves, and mediate NPY effects on tumor cell proliferation and tumoral blood supply. Clinically, tumoral NPY receptors may be targeted with NPY analogs coupled with adequate radionuclides or cytotoxic agents for a scintigraphic tumor imaging and/or tumor therapy.

Blood Vessels↗

Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies.

Intravascular ultrasound (IVUS) imaging is used along with X-ray coronary angiography to detect vessel pathologies. Manual analysis of IVUS images is slow and time-consuming and it is not feasible for clinical purposes. A semi-automated method is proposed to generate 3D reconstructions from IVUS video sequences, so that a fast diagnose can be easily done, quantifying plaque length and severity as well as plaque volume of the vessels under study. The methodology described in this work has four steps: a pre-processing of IVUS images, a segmentation of media-adventitia contour, a detection of intima and plaque and a 3D reconstruction of the vessel. Preprocessing is intended to remove noise from the images without blurring the edges. Segmentation of media-adventitia contour is achieved using active contours (snakes). In particular, we use the gradient vector flow (GVF) as external force for the snakes. The detection of lumen border is obtained taking into account gray-level information of the inner part of the previously detected contours. A knowledge-based approach is used to determine which level of gray corresponds statistically to the different regions of interest: intima, plaque and lumen. The catheter region is automatically discarded. An estimate of plaque type is also given. Finally, 3D reconstruction of all detected regions is made. The suitability of this methodology has been verified for the analysis and visualization of plaque length, stenosis severity, automatic detection of the most problematic regions, calculus of plaque volumes and a preliminary estimation of plaque type obtaining for automatic measures of lumen and vessel area an average error smaller than 1mm(2) (equivalent aproximately to 10% of the average measure), for calculus of plaque and lumen volume errors smaller than 0.5mm(3) (equivalent approximately to 20% of the average measure) and for plaque type estimates a mismatch of less than 8% in the analysed frames.

Blood Vessels↗