Articular surface material effect on metal-backed patellar components. A microscopic evaluation.

Abstract

This study evaluated patellar wear with three commonly used metallic surfaces against a polyethylene surface. Wear characteristics of metal-backed patellar components were tested against cobalt chromium, titanium alloy, and ion-implanted titanium alloy (IITi) articular surfaces. Adult bovine serum was used as a lubricant. The specimens were cycled at 2.9 Hz for 1 X 10(6) cycles. The axial load was 343.2 N at 0 degrees flexion and increased to 2255.6 N at 110 degrees flexion. After testing, the polyethylene and metal surfaces were examined for wear using scanning electron microscopy. Patellae tested against the titanium-alloy surfaces had severe abrasion, surface cold flow, and pitting. The patellae tested against IITi were similar to the titanium-alloy group at the edges of the components, and delamination of the surface layers occurred in the high stress areas. The patellae tested against cobalt-chromium alloy had the least wear. Among the three metal surfaces, the titanium surface had the most severe surface abrasion and the cobalt-chromium surface had the least. At higher power magnification (X500), the cobalt-chromium surface had minimal surface abrasion even in the high stress areas. The IITi and titanium surfaces had severe scratching and surface abrasion, but the titanium surfaces were clearly more severely affected. The ion-implanted surface appeared to have been worn away in the high stress areas. Ion implantation does not produce a major improvement in the effect the titanium-alloy surface has on the polyethylene but does improve the wear on the metal surface itself. The cobalt-chromium surface was less damaged than the titanium and IITi and also caused less damage to the polyethylene. This experiment suggests that titanium and ion-implanted titanium are inferior materials to cobalt chromium when used as an articular surface in total knee replacements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M T Milliano, L A Whiteside. 1991. Articular surface material effect on metal-backed patellar components. A microscopic evaluation.. https://pubmed.ncbi.nlm.nih.gov/1959273/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrochemical characterization of albumin protein on Ti-6AL-4V alloy immersed in a simulated plasma solution.

The effect of oxygen and albumin on the electrochemical behavior of a Ti-6Al-4V alloy immersed in a simulated inorganic plasma (SIP) solution was studied with a rotating-cylindrical electrode configuration to focus on the surface/electrolyte reactions. Potentiokinetic scans and electrochemical impedance spectroscopy have been used to characterize the interface by determining the passive current density and capacitance. For the polarization scans, an albumin addition of 37.7 mg/cm(3) to the SIP solution (oxygenated and unoxygenated) decreased the passive current density, indicating a lowering of the corrosive rate. The surface capacitance for the Ti-6Al-4V alloy immersed in a SIP solution averaged 13 microF/cm(2), which transformed after albumin addition (37.7 mg/cm(3)) from a potential independent behavior to the capacitance ranging from 23 to 6 microF/cm(2) with increasing potentials from -800 to 1500 mV(SCE), respectively, indicative of albumin adsorption. Within the same potential range and albumin addition to oxygenated solutions, the capacitances expanded slightly with a similar decreasing trend from 31 to 6 microF/cm(2), although the capacitance depicts an interaction between the hydrated passive film and the adsorbed albumin from -550 to 500 mV(SCE) in which the capacitance plateaued at 15 microF/cm(2). The hydrated porous oxide film results from the porous rutile layer reacting with H(2)O(2) formed as an intermediary component of oxygen reduction at the Ti-6Al-4V surface. The passive film-albumin interaction would affect the processing of titanium alloys in their surface preparation for biocompatibility, as well as determining the reactivity of titanium alloys to proteins.

Alloys↗

Fatigue-crack growth properties of thin-walled superelastic austenitic Nitinol tube for endovascular stents.

Over the past 10 years, the supereleastic nickel-titanium alloy Nitinol has found widespread application in the manufacture of small-scale biomedical devices, such as self-expanding endovascular stents. Although conventional stress/strain-life (S/N) analyses are invariably used as the primary method for design against fatigue loading and for predicting safe lifetimes, fracture mechanics-based methodologies provide a vital means of assessing the quantitative effect of defects on such lifetimes. Unfortunately, fracture mechanics studies on fatigue in Nitinol are scarce, and most results do not pertain to the (thin-walled tube) product forms that are typically used in the manufacture of endovascular stents. In the current work, we document the basic fatigue-crack growth properties of flattened thin-walled ( approximately 400 microm thick) Nitinol tubing in a 37 degrees C air environment. Crack-growth behavior is characterized over a wide range of growth rates ( approximately 6 orders of magnitude) and load ratios, that is, as a function of the alternating and maximum stress intensities, at 50 Hz. Limited experiments at both 5 and 50 Hz were also performed in 37 degrees C air and simulated body fluid to determine whether the cyclic frequency affects the fatigue behavior. Fatigue-crack growth-rate properties in such thin-walled Nitinol tube are found to be quite distinct from limited published data on other (mainly bulk) product forms of Nitinol, for example, bar and strip, both in terms of the relative fatigue thresholds and the variation in steady-state growth rates.

Alloys↗