Carpal orientation from computed reference axes.

Abstract

Carpal instability is usually diagnosed by abnormal two-plane radiographic angles. These angles are often unreliable. A method that eliminates interpretation of overlapping shadows and uses all of the carpal geometry should improve clinical diagnoses. The digital data from computed tomography scans can be manipulated to describe the carpal orientation in the normal wrist. The digital data from the computed tomography scans of twenty-two normal wrists were used to compute distances with and without directions between the volumetric centroids of the carpal bones. An expansion technique also extracted from the computed tomography data an orthogonal set of vectors, the principal axes. The first principal axis describes the longest dimension of each bone. The average angle produced by the first principal axes of the scaphoid and lunate was 23.6 degrees, scaphoid and capitate was 73.2 degrees, and the capitate and the lunate was 93.5 degrees. These computations represent new carpal axes and intercarpal angles that are not related to the commonly measured two-plane radiographic angles. They should prove helpful in the study of kinematics and pathomechanics in the wrist joint.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Belsole, D R Hilbelink, J A Llewellyn, M Dale, J A Ogden. 1991. Carpal orientation from computed reference axes.. https://doi.org/10.1016/s0363-5023(10)80018-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Automated solid models from serial section images.

A new method for creating unambiguous and complete boundary representation solid models with a hybrid polygonal/nonuniform rational B spline representation was developed and tested using computed tomography scans of the wrist. Polygon surface approximation was applied to a sequence of parallel planar outlines of individual bone elements in the wrist. An automated technique for the transformation of edge contours into solid models was implemented. This was performed using a custom batch file command sequence generator coupled to a commercially available mechanical computer-aided design and engineering software system known as I-DEAS (Structural Dynamics Research Corporation, Milford, OH). This transformation software allows the use of biomedical scan slice data with a solid modeler.

Carpal Bones