PubMed Health⌕ Search

PubMed · 1999635

Sinus node-atrioventricular node isolation: long-term results with the "corridor" operation for atrial fibrillation.

Abstract

The "corridor" operation is designed to restore sinus rhythm to patients with atrial fibrillation by electrically isolating the sinus node, a band of atrial tissue and the atrioventricular (AV) node from the remaining atrial tissue. Nine patients with drug-refractory atrial fibrillation underwent this operation; four patients had chronic atrial fibrillation and five had paroxysmal atrial fibrillation; the mean duration of symptoms was 12 +/- 8 years. Patient ages ranged from 25 to 68 years (mean 48 +/- 12). At preoperative electrophysiologic study, no patient had evidence of an accessory AV pathway or AV node reentry. Sinus node recovery time could not be determined in five patients because of recurrent atrial fibrillation during or before programmed stimulation. At operation the corridor of atrial tissue connecting the sinus and AV nodes was successfully isolated from the remaining left and right atrial tissue in all patients. One patient required early reoperation for recurrent atrial fibrillation before hospital discharge. At the predischarge electrophysiologic study, the corridor remained isolated in all patients except for one patient who had intermittent conduction between the corridor and excluded right atrium. One patient had nonsustained atrial fibrillation and one had atrial tachycardia evident in the corridor. Atypical AV node reentry of uncertain significance was induced in one other patient. Over a total follow-up of 191 patient months (mean 21 +/- 20), seven patients remained free of atrial fibrillation. Two patients had recurrent atrial fibrillation, which in one patient was effectively controlled by a single antiarrhythmic agent. A permanent pacemaker was implanted in four patients for sinus node dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J W Leitch, G Klein, R Yee, G Guiraudon. 1991-03-15. Sinus node-atrioventricular node isolation: long-term results with the "corridor" operation for atrial fibrillation.. https://doi.org/10.1016/0735-1097(91)90881-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Time-variant parametric estimation of transient quadratic phase couplings between heart rate components in healthy neonates.

The heart rate variability (HRV) can be taken as an indicator of the coordination of the cardio-respiratory rhythms. Bispectral analysis using a direct (fast Fourier transform based) and time-invariant approach has shown the occurrence of a quadratic phase coupling (QPC) between a low-frequency (LF: 0.1 Hz) and a high-frequency (HF: 0.4-0.6 Hz) component of the HRV during quiet sleep in healthy neonates. The low-frequency component corresponds to the Mayer-Traube-Hering waves in blood pressure and the high-frequency component to the respiratory sinus arrhythmia (RSA). Time-variant, parametric estimation of the bispectrum provides the possibility of quantifying QPC in the time course. Therefore, the aim of this work was a parametric, time-variant bispectral analysis of the neonatal HRV in the same neonates used in the direct, time-invariant approach. For the first time rhythms in the time course of QPC between the HF component and the LF component could be shown in the neonatal HRV.

Arrhythmia, Sinus↗

Toward understanding respiratory sinus arrhythmia: relations to cardiac vagal tone, evolution and biobehavioral functions.

Respiratory sinus arrhythmia (RSA, or high-frequency heart-rate variability) is frequently employed as an index of cardiac vagal tone or even believed to be a direct measure of vagal tone. However, there are many significant caveats regarding vagal tone interpretation: 1. Respiratory parameters can confound relations between RSA and cardiac vagal tone.2. Although intraindividual relations between RSA and cardiac vagal control are often strong, interindividual associations may be modest.3. RSA measurement is profoundly influenced by concurrent levels of momentary physical activity, which can bias estimation of individual differences in vagal tone.4. RSA magnitude is affected by beta-adrenergic tone.5. RSA and cardiac vagal tone can dissociate under certain circumstances.6. The polyvagal theory contains evolution-based speculations that relate RSA, vagal tone and behavioral phenomena. We present evidence that the polyvagal theory does not accurately depict evolution of vagal control of heart-rate variability, and that it ignores the phenomenon of cardiac aliasing and disregards the evolution of a functional role for vagal control of the heart, from cardiorespiratory synchrony in fish to RSA in mammals. Unawareness of these issues can lead to misinterpretation of cardiovascular autonomic mechanisms. On the other hand, RSA has been shown to often provide a reasonable reflection of cardiac vagal tone when the above-mentioned complexities are considered. Finally, a recent hypothesis is expanded upon, in which RSA plays a primary role in regulation of energy exchange by means of synchronizing respiratory and cardiovascular processes during metabolic and behavioral change.

Arrhythmia, Sinus↗

The many metrics of cardiac chronotropy: a pragmatic primer and a brief comparison of metrics.

This paper focuses on pragmatic issues in obtaining measures of cardiac vagal control, and overviews a set of freely available software tools for obtaining several widely used metrics that putatively reflect sympathetic and/or parasympathetic contributions to cardiac chronotropy. After an overview of those metrics, and a discussion of potential confounds and extraneous influences, an empirical examination of the relationships amongst these metrics is provided. This study examined 10 metrics in 96 unselected college students under conditions of resting baseline and serial paced arithmetic. Intercorrelations between metrics were very high. Factor analyses were conducted on the metrics reflecting variability in cardiac rate, once at baseline and again during mental arithmetic. Factor structure was highly stable across tasks, and included a factor that had high loadings of all variables except Toichi's "cardiac sympathetic index" (CSI), and a second factor that was defined predominantly by the CSI. Although generally highly correlated, the various metrics responded differently under challenge.

Arrhythmia, Sinus↗