PubMed HealthSearch

PubMed · 2002170

A parametric study of cochlear input impedance.

Abstract

In this paper various aspects of the cat cochlear input impedance Zc (omega) are implemented using a transmission line model having perilymph viscosity and a varying cross-sectional scalae area. These model results are then compared to the experimental results of Lynch et al. [J. Acoust. Soc. Am. 72, 108-130 (1982)]. From the model, the following observations are made about the cochlear input impedance: (a) Scalae area variations significantly alter the model Zc (omega); (b) the use of anatomically measured area improves the fits to the experimental data; (c) improved agreement between model and experimental phase is obtained when perilymph viscosity and tapering are included in the cochlear model for frequencies below approximately 150 Hz; (d) when model scalae tapering and perilymph viscosity are chosen to match physiological conditions, the effect of the helicotrema impedance on Zc (omega) is insignificant; and (e) the cochlear map, which is defined as the position of the basilar membrane peak displacement as a function of stimulus frequency, can have an important effect on Zc (omega) for frequencies below 500 Hz. A nonphysiological cochlear map can give rise to cochlear standing waves, which result in oscillations in Zc (omega). Scalae tapering and perilymph viscosity contribute significantly to the damping of these standing waves. These observations should dispel the previous notion that Zc (omega) is determined solely by parameters of the cochlea close to the stapes, and the notion that Zc (omega) is dominated by the helicotrema at low frequencies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Puria, J B Allen. 1991. A parametric study of cochlear input impedance.. https://doi.org/10.1121/1.400675

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Risk factors of otitis media with effusion during infancy.

UNLABELLED: Associations of possible risk factors with prevalence of otitis media with effusion (OME) were prospectively studied in a cohort of 250 infants, aged 0-2 years. In order to determine OME, otoscopy and tympanometry were performed at 3-monthly intervals beginning at term date. Eighteen epidemiologically relevant features were inventoried by means of standardized questionnaires. Multivariate analysis controlled for possible confounding factors. Prevalence of OME was most strongly associated with age (P-value < 0.001). Other factors significantly associated with the prevalence of OME (P-value < 0.05) were gestational age, birth weight, breastfeeding, day-care attendance, number of siblings, season, and parent-reported ear infection, hearing loss, mouth breathing and common cold. No significance was found for gender, date of birth, passive smoking, family history of otitis media, parental socio-economic status and histories of snoring and consultation of a physician. IN CONCLUSION: both intrinsic and extrinsic factors appear to play an important role in the prevalence of OME. Some of the risk factors appeared to be time-dependent.

Acoustic Impedance Tests

Tympanometry by general practitioners: reliable?

BACKGROUND: The diagnosis of otitis media with effusion (OME) is difficult using only medical history and otoscopy. Tympanometry may, therefore, be helpful in the diagnosis and follow-up of OME in general practice. Studies regarding the reliability of tympanogram production and validation of tympanogram outcome have been performed. OBJECTIVE: To gain insight into the usability of microtympanometry and the degree of agreement and accuracy of tympanogram classification in general practice. METHODS: Data were collected in the offices of 49 general practitioners (GP's). The usability of the microtymp was monitored against a checklist. GP's (39) classified 47 tympanograms according to Jerger's modified classification, designating them as 'OME', 'no OME' or 'interpretion impossible'. The gold standard was the consensus over the 47 tympanograms reached by three doctors very experienced in tympanometry. RESULTS: Of the general practitioners, 61% handled the microtymp faultlessly. The overall inter-observer agreement was moderate to substantial; with respect to the gold standard 74% of the general practitioners had a satisfactory to almost perfect agreement. These results were achieved after instruction and training; longer practice produced no significant improvement in the agreement. CONCLUSION: After training and instruction microtympanometry is a reliable diagnostic instrument in general practice. The classification of tympanograms is satisfactory. Classification problems arise when the curve is not a good one. Additional criteria for the assessment of the curves are proposed.

Acoustic Impedance Tests

Evaluation of the use of a questionnaire to detect hearing loss in babies in China.

A questionnaire was used to screen hearing of 1020 babies 6-8 months in China. All babies failing the questionnaire and 10% of those who passed were tested using auditory brainstem audiometry (ABR). Babies with unilateral or bilateral hearing thresholds 30 dBnHL or more were investigated to determine the cause of the hearing impairment. Sixty-seven failing the questionnaire were tested and 23 were confirmed to have a hearing loss, 20 with bilateral hearing impairment. The causes were: 13 otitis media with effusion (OME), one hypoxia, one genetic and five unknown. One child with an OME related hearing loss passed the screen. The sensitivity of the questionnaire was estimated to be 70%, specificity 96%.

Acoustic Impedance Tests